68
8. SCANS
Programmed scan
Programmed scan and Fine Programmed scan
Scan
Scan edge
P1 or P2
Scan edge
P2 or P1
Jump
Repeatedly scans between two Scan Edge
frequencies.
The edge frequencies are preset in P1 and P2 as
the default.
(P1: 0.500000 MHz / P2: 29.999999 MHz)
L
To change the P1 and P2 Scan Edge Memory
channels, see “Entering memory channel
contents” (p. 61) for details.
L
If the same frequencies are entered into P1 and
P2, the Programmed scan does not start.
L
The Fine Programmed scan is most effective in
the SSB, CW, and RTTY modes.
D
Programmed scan operation
1. Select the VFO mode in the Main band.
2. Select the operating mode (example: USB),
tuning step (1 kHz).
3. Display the SCAN screen.
MENU
»
SCAN
4. Touch [PROG] to start the Programmed scan.
L
“PROGRAM SCAN” blinks while scanning.
L
You can change the operating mode and the tuning
step while scanning.
Frequency before scan
Blinks
5. Touch [FINE] to switch to the Fine Programmed
scan.
L
While scanning, “FINE PROGRAM SCAN” blinks
instead of “PROGRAM SCAN.”
L
Touch [FINE] again to return to the Programmed
scan.
Blinks
6. To close the SCAN screen, push
EXIT
several