12-8
12
SET MODE
DATA2 MOD
MIC,ACC
Selects the desired connector(s) for modulation
input when data 2 mode (D2) is in use.
• MIC
: Use the signals from [MIC].
• ACC
: Use the signals from [ACC1] (pin 4).
• MIC,ACC : Use the signals from [MIC] and
[ACC1] (pin 4). (default)
• S/P DIF
: Use the signals from [S/P DIF].
• LAN
: Use the signals from [LAN].
DATA3 MOD
MIC
Selects the desired connector(s) for modulation
input when data 3 mode (D3) is in use.
• MIC
: Use the signals from [MIC]. (default)
• ACC
: Use the signals from [ACC1] (pin 4).
• MIC,ACC : Use the signals from [MIC] and
[ACC1] (pin 4).
• S/P DIF
: Use the signals from [S/P DIF].
• LAN
: Use the signals from [LAN].
SEND Relay Type
MOS-FET
Selects the switching relay type for [RELAY] from
Reed
and MOSFET.
Select the suitable relay type when connecting a
non-Icom linear amplifier.
•
Reed
: Use mechanical relay.
(16 V DC/0.5 A maximum)
• MOS-FET : Use semiconductor type relay.
(250 V/200 mA maximum
: default
)
External Meter Output
Auto
Selects the desired item for an external meter indi
-
cation.
• Auto
: Outputs the receiving signal strength
level during receive, and outputs the
selected level (selected with [METER]),
during transmit. (default)
• S
: Outputs the receiving signal strength
level during receive.
• Po
: Outputs the transmitting power level dur
-
ing transmit.
• SWR
: Outputs the VSWR level during transmit.
• ALC
: Outputs the ALC level during transmit.
• COMP : Outputs the compression level during
transmit.
• V
d
: Outputs the drain terminal voltage of the
final amplifier MOSFETs.
• I
d
: Outputs the drain current of the final am-
plifier MOSFETs.
External Meter Level
50%
Sets the output level for an external meter indication
within 0 to 100% range in 1% steps.
• Approximately 2.5 V at 50% (default) setting for full-scale
indication. (4.7 k
Ω
impedance)
■
ACC set mode
(continued)