14-4
D
Command table (continued)
14
CONTROL COMMAND
Cmd. Sub Cmd.
Data
Description
14
11
0000 to
0255
Send/read [AGC] level
(0000=max. CCW to 0255=max. CW)
12
0000 to
0255
Send/read NB level
(0000=0%, 0255=100%)
13
0000 to
0255
Send/read [DIGI-SEL] position
(0000=max. CCW to 0255=max. CW)
14
0000 to
0255
Send/read DRIVE gain
(0000=0%, 0255=100%)
15
0000 to
0255
Send/read Monitor gain
(0000=0%, 0255=100%)
16
0000 to
0255
Send/read VOX gain
(0000=0%, 0255=100%)
17
0000 to
0255
Send/read Anti VOX gain
(0000=0%, 0255=100%)
18
0000 to
0255
Send/read [CONTRAST] level
(0=max. CCW to 255=max. CW)
19
0000 to
0255
Send/read BRIGHT level
(0000=0%, 0255=100%)
15
01
00
Read squelch condition (squelch close)
01
Read squelch condition (squelch open)
02
0000 to
0255
Read S-meter level
(0000=S0, 0120=S9, 0241=S9+60 dB)
05
00
Read noise, S-meter squelch TSQL or
VSC status (squelch close)
01
Read noise, S-meter squelch TSQL or
VSC status (squelch open)
11
0000 to
0255
Read RF power meter
(0000=0 W, 0143=100 W, 0212=200 W)
12
0000 to
0255
Read SWR meter
( 0000=SWR1.0, 0048=SWR1.5,
0080=SWR2.0)
13
0000 to
0255
Read ALC meter (0000=0, 0120=Max.)
14
0000 to
0255
Read COMP meter
(0000=0 dB, 0130=15 dB, 0241=30 dB)
15
0000 to
0255
Read VD meter
(0151=44 V, 0180=48 V, 0211=52 V)
16
0000 to
0255
Read ID meter
(0000=0 A, 0165=10 A, 0241=15 A)
16
02
00
Preamp OFF
01
Preamp 1 ON
02
Preamp 2 ON
12
00
AGC OFF selection
01
AGC FAST selection
02
AGC MID selection
03
AGC SLOW selection
22
00
Noise blanker OFF
01
Noise blanker ON
32
00
Audio peak filter OFF
01
Audio peak filter WIDE ON (320 Hz is
selected when SHARP APF is set)
02
Audio peak filter MID ON (160 Hz is
selected when SHARP APF is set)
03
Audio peak filter NAR ON (80 Hz is
selected when SHARP APF is set)
40
00
Noise reduction OFF
01
Noise reduction ON
41
00
Auto notch function OFF
01
Auto notch function ON
42
00
Repeater tone OFF
01
Repeater tone ON
43
00
Tone squelch OFF
01
Tone squelch ON
Cmd. Sub Cmd.
Data
Description
16
44
00
Speech compressor OFF
01
Speech compressor ON
45
00
Monitor function OFF
01
Monitor function ON
46
00
VOX function OFF
01
VOX function ON
47
00
BK-IN function OFF
01
Semi BK-IN function ON
02
Full BK-IN function ON
48
00
Manual notch function OFF
01
Manual notch function ON
4C
00
VSC function OFF
01
VSC function ON
4D
00
AGC VR function OFF
01
AGC VR function ON
4E
00
DIGI-SEL function OFF
01
DIGI-SEL function ON
16
4F
00
Twin peak filter OFF
01
Twin peak filter ON
50
00
Dial lock function OFF
01
Dial lock function ON
53
00
ANT RX-I/O function OFF
01
ANT RX-I/O function ON
55
00
15 kHz roofing filter selection
01
6 kHz roofing filter selection
02
3 kHz roofing filter selection
56
00
SHARP selection for DSP filter type
01
SOFT selection for DSP filter type
57
00
WIDE selection for manual notch width
01
MID selection for manual notch width
02
NAR selection for manual notch width
58
00
WIDE selection for SSB transmit
bandwidh
01
MID selection for SSB transmit
bandwidth
02
NAR selection for SSB transmit
bandwidth
17
see p. 14-12 Send CW messages*
1
18
00
Turn ON the transceiver.
01
Turn OFF the transceiver.*
2
19
00
Read the transceiver ID
1A
00
see p. 14-13 Send/read memory contents
01
see p. 14-10 Send/read band stacking register
contents
02
see p. 14-10 Send/read memory keyer contents
03
00 to 49
Send/read the selected filter width
( SSB, CW, PSK: 00=50 Hz to
40=3600 Hz; RTTY: 00=50 Hz to
31=2700 Hz; AM: 00=200 Hz to 49=10
kHz)
04
00 to 13
Send/read the selected AGC time
constant
( 00=OFF, 01=0.1/0.3 sec., 13=6.0/8.0
sec.)
*
1
In the CW mode, if the [TRANSMIT] or an external TX switch is ON, or
the Break-in function is ON, a message will be transmitted as CW code
when you send it from your PC.
*
2
The power ON command (18 01) is available only when the trans-
ceiver is standby mode.