3-7
ADJUSTMENT
OPERATION
ADJUSTMENT
ITEM/POINT
VALUE
EXTERNAL
METER
-PREPARATION-
1
• Push [F-1] (PRESET) to enter the Preset menu.
–
–
-ADJUSTMENT-
2
1) Push [F-5] (ID-APC).
2) Turn the main dial to set the adjustment value to “11.0 A.”
3) Push [F-7] (SET).
• Returns to the preset menu.
[ID APC REF]
“11.0 A”
(On the screen)
3
1) Connect a voltmeter to the [METER] terminal.
2) Push [F-1] (Ext Met) to enter the External Meter adjust-
ment mode.
–
–
4
1) Turn the main dial to set the output voltage to “0 V.”
2) Push [F-7] (SET).
[EXT-METER A]
0 V
5
1) Turn the main dial to set the output voltage to “0 V.”
2) Push [F-7] (SET).
[EXT-METER B]
0 V
6
1) Push [F-3] (EXIT).
•
Returns to the External Meter adjustment mode.
2) Push [F-6] (EXIT).
• Returns to the main adjustment menu.
–
–
3-3 PRESET ADJUSTMENTS
• PRESET screen
RF-A UNIT
RF-A UNIT
MAIN UNIT