3-9
3-5 ID ADJUSTMENTS
ADJUSTMENT
OPERATION
ADJUSTMENT
ITEM/POINT
VALUE
IDLING CURRENT
-PREPARATION-
1
1) Connect an Audio Generator to the MIC input [MIC], and
then set it as:
• Frequency:
1.5 kHz
• Level:
10 mVrms
2) Connect an RF power meter (Terminated type) to the
[ANT1] connector.
3) Connect a 100
dummy load (SWR=2) to the [ANT2] con-
nector.
4) Push [F-3] (ID).
•
Enters to the Idling Current adjustment mode.
• "FINAL ID SET" is displayed.
–
–
-ADJUSTMENT-
2
• Push [F-7].
• "FINAL1 IDV" is displayed.
[FINAL ID SET]
Push [F-7].
3
• Push [F-7].
• "FINAL2 IDV" is displayed.
[FINAL1 IDV]
Push [F-7].
4
• Push [F-7].
• "DRIVER ID SET" is displayed.
[FINAL2 IDV]
Push [F-7].
5
• Push [F-7].
• "DRIVER IDV" is displayed.
[DRIVER ID SET]
Push [F-7].
6
• Push [F-7].
• Returns to the main adjustment menu.
[DRIVER IDV]
Push [F-7].
• ID adjustment screen
RF-A UNIT
RF-A UNIT
MAIN UNIT