ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
PREPARATION
–
• Connect an SSG to [ANT1], and
then set it as;
Frequency : 14.1515 MHz
Modulation : None
Level
†
:
+20 dBu (–87 dBm)
–
–
–
TOTAL GAIN
1 • Display: "Total Gain HF POFF"
• Receiving
–
–
–
Push [F-5].
(Beeps sound
20–30 sec. later)
2 • Display: "Total Gain HF PON"
• Receiving
–
–
–
EXTERNAL AGC
3 • Display: "AGC (HF)"
• Receiving
• Set the SSG as;
Level
†
:
+70 dBu (–37 dBm)
–
–
Push [F-5].
(Beeps sound
40 sec. later)
S-METER
NOTE: DO NOT
change the output level of the SSG until the beeps sound.
4 • Display: "S0 Level HF"
• Receiving
• Set the SSG as;
Level
: OFF
–
–
Push [F-5].
(Beep sounds,
and then
another beeps
sound
0.5 sec. later)
5 • Display: "S9 Level HF"
• Receiving
• Set the SSG as;
Level
†
:
+34 dBu (–73 dBm)
Push [F-5].
(Beep sounds,
and then
another beeps
sound
1 sec. later)
6 • Display: "S9+60 Level HF"
• Receiving
• Set the SSG as;
Level
†
:
+90 dBu (–17 dBm)
Automatically returns to the receive adjustment menu.
¤
RECEIVE ADJUSTMENTS
• RECEIVE ADJUSTMENTS (HF band)
• Receive adjustment menu.
MENU
H F
V H F
U H F
RX
Reterns to the previous screen.
Stores the value and move to the next item.
Starts the receive adjustments (HF band).
(See below)
Starts the receive adjustments (VHF).
(Page 4-19)
Starts the transmit adjustments (UHF).
(Page 4-20)
4 - 18
†
; The output level of the standard signal generator (SSG) is indicated as the SSG’s terminated circuit.