ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
TUNED BPF
NOTE: DO NOT
change the output level of the SSG until the beeps sound.
1 • Display: "Tuned BPF 1-1 UHF"
• Transmitting
• Connect an SSG to [430MHz
ANT], and then set it as;
Frequency : 420.2015 MHz
Modulation : None
Level
†
:
+20 dBu (–87 dBm)
–
–
Push [F-5].
(A beep sounds,
and then
another beeps
sound 2.5 sec.
later)
2 • Display: "Tuned BPF 1-2 UHF"
• Transmitting
3 • Display: "Tuned BPF 2-1 UHF"
• Transmitting
• Set the SSG as;
Frequency : 440.2015 MHz
4 • Display: "Tuned BPF 2-2 UHF"
• Transmitting
5 • Display: "Tuned BPF 3-1 UHF"
• Transmitting
• Set the SSG as;
Frequency : 479.8015 MHz
6 • Display: "Tuned BPF 3-2 UHF"
• Transmitting
TOTAL GAIN
7 • Display: "Total Gain UHF"
• Receiving
• Set the SSG as;
Frequency : 435.2015 MHz
Modulation : None
Level
†
:
0 dBu (–107 dBm)
–
–
Push [F-5].
(Beeps sound
20–30 sec. later)
EXTERNAL AGC
8 • Display: "AGC (UHF)"
• Receiving
• Set the SSG as;
Level
†
:
+60 dBu (–47 dBm)
–
–
Push [F-5].
(Beeps sound
40 sec. later)
S-METER
NOTE: DO NOT
change the output level of the SSG until the beeps sound.
9 • Display: "S0 Level UHF"
• Receiving
• Set the SSG as;
Level
: OFF
–
–
Push [F-5].
(Beep sounds,
and then
another beeps
sound
0.5 sec. later)
10 • Display: "S9 Level UHF"
• Receiving
• Set the SSG as;
Level
†
:
+10 dBu (–97 dBm)
Push [F-5].
(Beep sounds,
and then
another beeps
sound
1 sec. later)
11 • Display: "S9+60 Level UHF"
• Receiving
• Set the SSG as;
Level
†
:
+70 dBu (–37 dBm)
Automatically returns to the receive adjustment menu.
• RECEIVE ADJUSTMENTS (UHF band)
4 - 20
†