(Replacement page)
Jun. 2012
• RECEIVE ADJUSTMENT
1) Select an adjustment item using cursor or [
↑
] / [
↓
] keys of the PC’s keyboard.
2) Set or modify the adjustment value as specifi ed using [
←
] / [
→
] keys of the PC’s keyboard, then push the [ENTER] key.
ADJUSTMENT
ADJUSTMENT CONDI-
TION
OPERATION
ADJUST-
MENT
ITEM/
POINT
VALUE
RECEIVE
SENSITIVITY
-Preparation-
1 • Connect an SSG to the RX
antenna connector.
• Set the SSG as;
Level
†
: +20 dBµ (–87 dBm)
Modulation
: 1 kHz
Deviation
: 3.5 kHz
–
–
-Adjust-
2 • CH.
: 1-27
• Receiving
1) Set the SSG as;
Frequency
: 136.100 MHz
2) Select the item
[BPF C ALL]
, then
push the [ENTER] key.
[BPF C
ALL]
(Automatic
adjustment)
S-METER
-Preparation-
NOTE:
"RECEIVE SENSITIVITY" MUST be adjusted before "S-METER." When "RECEIVE SENSITIVITY" is
re-adjusted, "S-METER" MUST be re-adjusted too.
1 • Connect an SSG to the RX
antenna connector.
• Set the SSG as;
Frequency
: 173.900 MHz
Modulation
: 1 kHz
Deviation
: 3.5 kHz
–
–
-Adjust-
(S3 level)
2 • CH.
: 1-29
• Receiving
1) Set the SSG as;
Level
†
: +23 dBu (–84 dBm)
2) Select the item
[RSSI S3 Level]
,
then push the [ENTER] key to store
the adjust value.
[RSSI S3
Level]
(Automatic
adjustment)
(S1 level)
3 • CH.
: 1-29
• Receiving
1) Set the SSG as;
Level
†
: –7 dBu (–114 dBm)
2) Select the item
[RSSI S1 Level]
,
then push the [ENTER] key, to store
the adjust value.
[RSSI S1
Level]
(Automatic
adjustment)
SQUELCH
-Preparation-
1
–
• Set the item
[SQL Level]
to "2."
[SQL Level]
"2"
2 • Connect an SSG to the RX
antenna connector.
• Set the SSG as;
Frequency
: 173.900 MHz
Modulation
: 1 kHz
Deviation
: 3.5 kHz
Level
†
:
–12 dBu (–119 dBm)
–
–
-Adjust-
3 • CH.
: 1-30
• Receiving
1) Decrease the adjustment value
[SQL]
to close the squelch once,
then increase the value to open the
squelch.
2) Select the item
[SQL]
, then push
the [ENTER] key to store the adjust
value.
[SQL]
(Automatic
adjustment)
†
; The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
6 - 9