4-3
4-2 ADJUSTMENT
ADJUSTMENT
ADJUSTMENT DISPLAY
SETTING CONDITION
VALUE
ITEM
FREQUENCY MODE
SUB
Reference
frequency
0 A REF1
1304.490
FM
–
Connect the spectrum analyzer to the antenna
connector and set it to:
Span:
1 kHz
RBW:
30 Hz
VBW:
30 Hz
1038.25 MHz
±50 Hz
1 A REF2
1304.490
FM
–
WFM S
curve
2 A WFM
1304.900
WFM
–
Connect the standard signal generator to the
antenna connector and set it to:
Frequency: 1304.900 MHz
Modulation: Non
Level:
+60 dBµ (–47 dBm)
Push
[ENTER].
(Automatic
adjustment)
AFC
3 A AFC1
1304.900
FM
–
4 B AFC2
519.900
FM
–
Set the standard signal generator to:
Frequency: 519.900 MHz
BPF
5 B BPFL
108.020
FM
–
Set the standard signal generator to:
Frequency: The same as the displayed
frequency.
6 B BPFM
144.020
FM
–
7 B BPFH
173.980
FM
–
8 B BPFL
174.020
FM
–
9 B BPFM
217.000
FM
–
10 B BPFH
259.980
FM
–
11 B BPFL
260.020
FM
–
12 B BPFM
320.020
FM
–
13 B BPFH
379.980
FM
–
14 B BPFL
380.020
FM
–
15 B BPFM
450.020
FM
–
16 B BPFH
519.980
FM
–
S-meter
curve
17 A
SC0
145.100
FM
145.100 Set the standard signal generator to:
Frequency: 145.100 MHz
Level:
–10 dBµ (–117 dBm)
18 B
SC0
145.100
FM
145.100
19 A
SC3
145.100
FM
145.100 Set the standard signal generator to:
Level:
–6 dBµ (–113 dBm)
20 B
SC3
145.100
FM
145.100
21 A SCF
145.100
FM
145.100 Set the standard signal generator to:
Level:
+5 dBµ (–102 dBm)
22 B SCF
145.100
FM
145.100
23 A
SC0
145.100
WFM 145.100 Set the standard signal generator to:
Level:
+7 dBµ (–100 dBm)
24 A
SC3
145.100
WFM 145.100 Set the standard signal generator to:
Level:
+11 dBµ (–96 dBm)
25 A SCF
145.100
WFM 145.100 Set the standard signal generator to:
Level:
+25 dBµ (–82 dBm)
26 A
SC0
145.100
LSB
145.100 Set the standard signal generator to:
Frequency: 145.0985 MHz
Level:
–10 dBµ (–117 dBm)
27 A
SC3
145.100
LSB
145.100 Set the standard signal generator to:
Level:
–6 dBµ (–113 dBm)
28 A SCF
145.100
LSB
145.100 Set the standard signal generator to:
Level:
+5 dBµ (–102 dBm)
S-meter
(S3)
29 A
S3
22.500
FM
145.100 Set the standard signal generator to:
Frequency: The same as the displayed
frequency on the MAIN band.
Level:
–6 dBµ (–113 dBm)
30 A
S3
40.100
FM
145.100
31 A
S3
63.100
FM
63.100
32 A
S3
92.100
FM
145.100
33 A
S3
217.100
FM
217.100
34 B
S3
217.100
FM
217.100
35 A
S3
320.100
FM
320.100
36 B
S3
320.100
FM
320.100
37 A
S3
470.100
FM
470.100
38 B
S3
470.100
FM
470.100
39 A
S3
650.100
FM
145.100
40 A
S3
1167.500
FM
145.100
41 A
S3
2341.100
FM
145.100 Set the standard signal generator to:
Level:
+2 dBµ (–105 dBm)