PANEL DESCRIPTION
CONNECTION AND OPERATION
q
Connect the AC power cable of the PS-300 to an AC out-
let.
w
Turn the PS-300 ON, then adjust the suitable output volt-
age.
• “ I ” : ON
(Power indicator lights green)
• “O” : OFF (Power indicator goes off)
e
Turn the PS-300 OFF, and make sure the equipment's
power is also OFF.
r
Connect the DC power cable to the PS-300 and the
equipment's DC power input.
t
Turn the PS-300 ON.
y
Turn the equipment ON.
u
To turn OFF the system, turn the equipment power OFF,
then the PS-300 in sequence.
OVERLOAD AND SHORT CIRCUIT PROTECTOR
The PS-300 has overload and short circuit protection circuits.
When the PS-300 is under the condition of overload or the
+
and
_
lines are shorted, the PS-300 limits the output current
and the overload indicator lights red. In such a case, turn OFF
the PS-300, remove the source of the problem, wait several
seconds, then turn it ON again.
V
I
–
+
– +
–
+
O
A
w
q
!0
!1
i
e
r
t
u
y
o
FRONT PANEL
q
OVERLOAD INDICATOR
Lights red when the PS-300 is under the condition of over-
load or the
+
and
_
lines are shorted.
w
AMPERE METER
Shows the driving current.
e
VOLTMETER
Shows the output voltage.
r
POWER INDICATOR
Power indicator lights green when the PS-300 is turned
ON.
t
POWER SWITCH
Turns the PS-300 power ON or OFF.
y
DC OUTPUTS (Max. 3 A)
Connect DC power cables.
u
DC OUTPUTS (Max. 30 A)
Connect DC power cables.
i
CONTROLLER
Adjusts the DC output voltage within 1–15 V.
REAR PANEL
o
COOLING FAN
!0
FUSE HOLDER
5 A fuse (F5AL250V) is installed.
!1
AC POWER CABLE
Connects to the AC outlet.
CURRENT CAPACITY
0
10
20
30
2
1
4
6
8
10
12
14
Output Voltage [V]
Output Current [A]
15
Current capacities of the PS-300 depend on their output
voltage as per the graph at right. (The graph shows typical
values for reference.)