108
VE-PG2 SETTING SCREEN
3
3-19 TRX/EXT EXT output (EXT OUT) (Continued)
ï
EXT voice terminal setting (Continued)
Place the mouse pointer on �Connection setting,�� and then on �TRX/EXT,�� and then
click �EXT Output (EXT OUT)�� shown on the list.
e
F����-�u��
Set the time until the AF signal is muted.
(Default: 1.5 seconds)
Selectable from Disable, 0.5, 1, 1.5, 2 or 3.
Set the delay time from when a DTMF signal is received by the VE-PG2, until it
gradually decreases the currently broadcast audio, that is sent to the [OUT] port
until no sound is heard.
• Set �EXT I/O port�� to �Separate mode.��
• Set �Input connection port�� to �EXT Output.�� (p. 102)
• Set �Priority level setting�� to �Priority calling�� or �High priority calling.��
• Fade-out is not used before an emergency broadcast is sent.
• This item appears only when you select �Separate mode�� in �EXT I/O port�� in �Operating
mode.��
r
F����-��
Set the time until the mute is cancelled.
(Default: 1.5 seconds)
Selectable from Disable, 0.5, 1, 1.5, 2 or 3.
Set the delay time from when a DTMF signal is received by the VE-PG2, until it
gradually increases the audio, that was sent through the [OUT] port, to its original
s original
original
level.
• Set �EXT I/O port�� to �Separate mode.��
• Set �Input connection port�� to �EXT Output.�� (p. 102)
• Set �Priority level setting�� to �Priority calling�� or �High priority calling.��
• Fade-in is not used after an emergency broadcast is sent.
• This item appears only when you select �Separate mode�� in �EXT I/O port�� in �Operating
mode.��
■
Connection setting (Selective call mode)
e
r