C����������� ������
Set the emergency signal send timing to the IP network.
(Default: See EXT Input setting)
• See EXT Input setting
: When the emergency signal enter from the [IN] port, the
connection timing is dependent on the �Valid timing�� setting. (p. 79)
When the signal is received at the port that is set in �My station
port number,�� (p. 72) the VE-PG2 outputs the emergency notice to
the selected port. (p. 129)
• Transmit only
: When the emergency signal enter from the [IN] port, the
connection timing is dependent on the �Valid timing�� setting. (p. 79)
When the signal is received at the port that is set in �My station
port number,�� (p. 72) the VE-PG2 does not output the signal.
• Receive only
: When the emergency signal enter from the [IN] port, the VE-PG2
does not output the signal.
When the signal is received at the port that is set in �My station
port number,�� (p. 72) the VE-PG2 outputs the emergency notice to
the selected port. (p. 129)