5
BRIDGE MODE SETTING SCREEN
5-55
7. [Bridge Connection] Menu
M
Bridge Connection Point (continued)
[Bridge Connection]–[Bridge Connection]
t
My Station Port Number …
Enter the port number to receive the audio signal.
• This port number is also for the audio transmit port.
• Setting range: Even numbers between 2 and 65534
(Some numbers may not be acceptable.)
• The set port number (RTP) and the port 1 (RTCP) are used for the
communication.
• When using in the Unicast mode, do not set the port number which is
already used by another connection setting.
• The default number differs, depending on the setting.
(Default: 21504(Digital Transceiver1(D-TRX1)),
21506(Digital Transceiver2(D-TRX2)),
21508(Digital Transceiver3(D-TRX3)),
21510(Digital Transceiver4(D-TRX4)),
21520(Emergency Notice),
When [IP Communication Mode] is set to [Unicast]:
21500(Transceiver1(TRX1)),
21502(Transceiver2(TRX2)),
21512(External Input1 (EXT1), External I/O 1(EXT1)),
21514(External Output1 (EXT1)),
21516(External Input2 (EXT2), External I/O 2(EXT2)),
21518(External Output2 (EXT2)),
When [IP Communication Mode] is set to [Multicast]:
22510(Transceiver1(TRX1), Transceiver2(TRX2), External
Input1 (EXT1), External Output1 (EXT1), External I/O
1(EXT1), External Input2 (EXT2), External Output2 (EXT2),
External I/O 2(EXT2))