5
BRIDGE MODE SETTING SCREEN
5-102
M
Abnormal Condition Monitoring
Set the monitor function for the communication error.
9. [Expansion] Menu (continued)
[Expansion]–[Abnormal Condition Monitoring]
• This is an example.
q
LAN Port Downlink ………
Monitoring
Select “Enable” to automatically detect the communication error.
When the Ethernet cable disconnects from the VE-PG3’s [LAN] port, the
[WAN] LED lights Orange, and the error message is displayed on the
“SYSLOG” screen in the “Information” menu.
(Default: Disable)
Control Output
Select "Enable" to output the error detect signal from the B1/B2 terminal
(+/–).
(Default: Disable)
• Select "Relay circuit" in the Control Circuit] item on the [EXT Output](1/2), or
[EXT I/O](1/2) screen.
While the error detect signal sends, the VE-PG3 cannot receive signals from
the external device that is connected to the B1/B2 terminal (+/–).