6
CONVERTER MODE SETTING SCREEN
6-105
9. [Port Settings] Menu (continued)
M
Voice Transmission Control to a Bridge Connection
The VOX (voice operated transmission) function automatically switches the connected transceiver to transmit,
when the VE-PG3 receives the audio signal through the network.
q
Attack Time ………………
Select the TX attack time in 0 to 2000 millisecond step. It is the delay time
before the VOX switch turns ON after an audio signal is received through the
network.
(Default: 50)
Range: 0 to 2000 milliseconds
w
Release Time ……………
Select the RX delay time in 5 millisecond step. The time is the delay for the
VOX switch to turn OFF after no audio signal is received through the network.
Range: 5 to 2000 milliseconds
(Default: 500)
e
Voice Delay ………………
Set the audio signal buffer time to prevent intermittent audio in 5 millisecond
step.
(Default: 200)
Range: 0 to 500 milliseconds
r
Voice Threshold …………
Set the voice threshold level. The VOX function automatically switches
between receive and transmit according to this threshold level.
Range: 0 to 100 %
(Default: 40)
• Lower values make the VOX function more sensitive to the audio signal.
[Port Settings]–[Bridge 1–Bridge 4]