background image

Page 5 

IMPORTANT READ THESE NOTES BEFORE CONNECTING TO AC MAINS! 

 

2 SET UP GUIDE  

 

1. Unpack unit carefully

.  Make  sure  that  it  is  in 

good condition. If not report to Icon Audio. It is 
important that you keep the packaging for 
warranty/service return. The contents of the box are:- 
1x CDX1, 2x 6SN7, 1x EZ80, 1x 0D3, 1x mains 
cable, 1x remote control. 1x instruction manual 

 

2. If Necessary fit the valves or check that they 
are firmly in place as shown on 

PREVIOUS PAGE 

INSERTION DIAGRAM.  

Fit the valves according to the type printed on the 
chassis. 

The 2 6SN7s should be on the right hand 

side when viewed from the front. With the 0D3 to the 
left. The EZ80 has a unique small 9 pin socket.

 

Be careful to align the central “spigot” of the 
6SN7 and 0D3 valves before insertion. They can 
be easily broken and is not covered by the 
warranty! 

NOTE: The 0D3 and 6SN7s are NOT 
interchangeable! This will result in damage and 
could be dangerous! 

 

3. Connect to amplifier, or pre amplifier. USE THE 
“VALVE OUTPUT” RCA SOCKETS. If you are 
intending to connect directly to a power amplifier, you 
will need some form of volume control such as our 
“Passive” pre-amp. The connections marked “AUDIO 
OUTPUT” are transistor output only. 

 

4. Before connecting to AC power, Check that the 
power switch on the front is “off”. For normal CD 
playing the front selector switch should be in the “CD” 
position (otherwise there will be no sound). Then 
connect the supplied IEC mains lead to a 220-240v 
supply. 

If for some reason the UK welded plug 

must be removed, please remove plug fuse and 
dispose of immediately.

 (As they can be a danger 

to children if plugged in). The replacement plug 
should be wired in the following way Brown to Live 
terminal, Blue to Neutral terminal and Green/Yellow 
to Earth terminal. 

 

5. 

Connect to your amplifier using the “valve 

output” RCA output sockets. The other outputs are 
not valve output. The 3 pin Cannon sockets offer 
“balanced” output which is also not using the valve 
stage. 
 
6. Using the CD Player as a “DAC”. 
Connect a CD Transport to either the OPTICAL or 
CO AX socket on the rear. Select the appropriate 
input on the front panel. Your signal will be now be 
decoded through the CDX1 DAC and valve 
analogue circuits. 

 

SWITCH ON!

 The green fluorescent display should 

light up. After about 30 seconds the valve regulator 
will start. After this time the player is ready for use 
in the normal way. The EZ80 rectifier and the two 
6SN7s will have a visible heater glow (when 
viewed from a certain angle). 

 

7 All these things are normal for the CDX1 

A, Valves can get very hot, BEWARE! 
B, The left transformer cover will get quite warm 
C, Audio valves may be a little microphonic. 
D, Mobile phone ‘breakthrough’ is normal. 
E, Some CDR CDs may not play 
F, Some CDRW CDs may not play. 

 

8 Health and Safety

. The valves when operating 

have hot to the touch surface temperatures. Keep 
out of reach of children and pets. Always unplug 
from power when making adjustments. 

Like all 

electronic devices there are potentially lethal 
high voltages inside, which when switched off 
can take twenty minutes to discharge!

 Do not 

remove the cover unless you are a competent 
engineer. There are no user serviceable parts 
inside. 

Like other household electrical 

appliances do not leave unattended whilst 
switched on.

 Do not use valves other than 

specified

.  

 

 

Summary of Contents for CDX1

Page 1: ...s in audio we have paid great attention to eliminating Radio Frequency interference from the audio output something ever present in the high speed digital processing To do this we have no less than si...

Page 2: ...perienced with hi fi please read the quick set up guide Should you be uncertain about anything please contact your dealer or us for advice Valve equipment does need a little more attention than their...

Page 3: ...st Check input N A Output Valve Bias level N A Sound Quality Channel Balance Valve Microphony Valve Seating Noise level RF Test Display brightness Serial No sticker and recorded Mains voltage 110 120...

Page 4: ...R USE ONLY THE VALVES INDICATED OR DIRECT EQUIVALENT On Off Input Select CD Drawer Open Play Back Fwd Stop Random CD Co Ax Optical insert label up Close Pause Track Play Digital In Out Transistor Outp...

Page 5: ...of immediately As they can be a danger to children if plugged in The replacement plug should be wired in the following way Brown to Live terminal Blue to Neutral terminal and Green Yellow to Earth ter...

Page 6: ...se anything wet on the amplifier and always clean with the power disconnected 5 Trouble Shooting CD Player Dead Check the fuse in the UK supplied IEC plug You could also try another IEC cable Also che...

Page 7: ...es marked 6SN7 6N8 CV181 0D3 and EZ80 Use only valves which you know to be new or good condition Take care that you orient the valve correctly before inserting and removing Line up the centre Spigot f...

Page 8: ...reported within three days of receipt The CDX1 is designed for normal domestic hi fi use It is not guaranteed for commercial Public Address use or use in other situations The guarantee becomes void if...

Reviews: