background image

Page 6 

switched  on  when  it  is  not  in  use.  It  is  using 
electricity and as valves have a finite life.  

 

‘Burning in’ 

Although  the  amplifier  should  sound  good  within 
about 10 mins it can take  up to an hour to sound 
at its best and will take several months of regular 
use before it is fully 

‘run in’. 

 

Upgrading Valves! 

Quality  valves  should  sound  better  and  have  a 
better  service.  The  valves  supplied  with  selected 
models  are  the  result  of  careful  comparison  with 
other makes. But beware of paying a premium for 

“New Old Stock” valves where you may be paying 
for  rarity  value  and  not  performance.  Icon  Audio 
normally keep a range of upgrade valves in stock. 

 

Cabinet Care 

To remove dust we suggest gentle brushing of the 
polished  stainless  steel  cabinet  with  a  soft 
paintbrush.  Other  marks  can  usually  be  removed 
with  a  damp  cloth.  The  Perspex  valve  cover  may 
need  a  gentle  wipe  with  soapy  water  and  drying 
with  a  duster.  Never  use  anything  wet  on  the 
amplifier,  and  always  clean  with  the  power 
disconnected.  

 

5 Trouble Shooting 

Amplifier Dead 

Check the 3 amp mains fuse at the back of the amplifier. 
To gain access, remove the mains lead. The fuse is in a 
small  plastic  drawer,  which  forms  part  of  the  socket 
assembly.  To  open  insert  a  flat  blade  screwdriver  or 
similar  and  prise  open. 

The  fuse  in  use  is  the 

innermost

 the outer is a spare. Should the replacement 

fuse  also  blow  there  is  a  fault  you  should  disconnect 
from  the  mains  and  seek  qualified  help  or  Icon  Audio. 
Replacements should be 3 

Amp ‘anti-surge’. 

The  fuse  in  the  wall  plug  should  be  a  3  or  5  amp  fuse, 
although  unlikely  to  fail,  this  should  be  checked  if  the 
amplifier fuse is OK. 

There  is  also  a  HT  fuse  inside  the  amplifier.  This 
would not normally blow unless there is a valve fault 
or an overload condition. This should be checked by 
your  dealer,  or  only  if  you  feel  competent. 
Disconnect amplifier from the mains power and wait 
20  minutes  (since  last  working)  before  removing 
bottom  plate.  If  the  HT  fuse  has  blown,  there  are 
replacements 

inside. 

Replace 

bottom 

cover 

afterwards  and  check  bias  immediately  after 
switching on. 

 

No sound 

Have you selected the right input? Is the 

“Tape Monitor” 

switch  up?  Are  all  the  connections  OK?  Is  everything 
switched on? Are the speakers connected? 

Distorted sound. 

Could  be  your  source,  the  speakers  or  the  amplifier, 
check  all  wiring,  and  try  swapping  things  around  to 
eliminate or prove which component if the problem. 
Left  or  right  amplifier?  If  both  probably  the  source  unit. 
Try another source. If one amplifier is distorted check the 
bias.  No  bias  reading  means  either  a  fuse  blown  or  a 
faulty  valve.  Distorted  sound  at  higher  volumes  may  be 
because  one  of  the  output  845  valves  is  not  working. 
This could be due a faulty 845 or one of the 845 internal 
fuses blowing. A symptom of this would be no 0.4V bias 
voltage at the test point.  Also the valve would not be as 
hot as the others. Refer to an engineer or to Icon Audio. 
Spare  internal  fuses  are  secured  inside  the  chassis. 
Replacements  are  available  free  of  charge  from  Icon 
Audio. 

Hum Problems 

If  you  experience  hum,  try  disconnecting  all  inputs,  if 
hum persists this is probably an amplifier fault.  
If  not,  identify  which  input is  causing  hum. Connect  one 
input at a time. A common cause 

is a ‘hum loop’ caused 

by  having  too  many  earths,  and  may  be  identified  by 
unplugging  each  input  source  from  the  mains.  One 
remedy for this is to use an interconnect which only has 

the  screen  connected  at  one  end.  Other  causes  of 
low-level  hum  can  be  from  adjacent  equipment,  so 
experiment  with  moving  equipment  around  to  see  if 
this makes the hum better or worse. 

 

Strange noises coming from speakers 

Turn  volume  to  minimum  on  unused  input,  if  the 
noise  disappears,  the  fault  is  with  the  source  or  the 
connection.  If  noise  persists,  the  problem  is  with 
amplifier. 

 

If  a  whole  output  valve  glows  red  (other  than  the 
heater),  often  accompanied  by  a  hum  through  the 
speakers,  switch  off  immediately,  and  refer  to  Icon 
Audio  or  a  service  engineer,  as  this  could  be  valve 
failure. 

 

Service: 

Should  you  suspect  a  problem,  you  could 

return  the  unit  to  your  dealer  or  Icon  Audio  for  a 
periodic service or return the valves for testing free of 
charge.  You  should  carefully  remove  the  valves  (the 
845s  should  be  held  by  the  base  when  removing,  to 
prevent damage) numbering them with a marker from 
left  to  right  as  you  do  so  in  order  that  that  may  be 
replaced  in  the  same  position.  They  should  be  well 
packed in cardboard & foam or similar, and returned 
to  Icon  Audio  for  testing.  (Valves  are  very  rugged  if 
packed properly). 

 

Mains Supply 

This  amplifier  is  hard  wired  to  work  on  230/240v  ac. 
The  transformer  may  be  re-configured  for  110/120v 
ac  by  a  qualified  engineer.  Contact  for  more 
information. 
 

This manual is provided for guidance only, and is not 
intended  as  a  comprehensive  service  manual.  In 
case  of  problems  you  should  refer  to  your  dealer  or 
directly to Icon Audio. 

Summary of Contents for MB 845

Page 1: ...roduction is a long chain of events that includes the recording editing mixing etc before being transferred to a medium such as LP Digital etc before being played through your own source unit the ampl...

Page 2: ...min 6 hour test Check input Output Valve Bias level v Sound Quality Channel Balance Valve Microphony Valve Seating Hum level L R mv RF Test LED brightness Serial No sticker and recorded Mains voltage...

Page 3: ...Page 3...

Page 4: ...rminal and Green Yellow to Earth terminal 6 SWITCH ON The blue mains indicator should light up The 845s will glow bright yellow You will likely hear a humming noise for about 30 secs this is normal Af...

Page 5: ...ystem up and play some music with plenty of bass e g dance music preferably in mono FM tuners are usually switchable to mono and stand the speakers close together If correct you should hear plenty of...

Page 6: ...things around to eliminate or prove which component if the problem Left or right amplifier If both probably the source unit Try another source If one amplifier is distorted check the bias No bias read...

Page 7: ...to the valve on test Set the Icon meter to 2000mv or the black mark See pics Making the ve connection 3 Checking Bias You should get a reading of ideally 400mV if each valve is conducting correctly Bu...

Page 8: ...ise yourself with the procedure If changing all the 845s be ready to adjust the bias in order not to overload the power supply Don t worry how low the reading goes this will not cause damage Do final...

Page 9: ...omestic hi fi use It is not guaranteed for commercial Public Address use or use in other situations The guarantee becomes void if the unit has been modified in any way not approved by Icon Audio 10 Pa...