Page 2
2 Final Inspection - Your Guarantee of Quality
To assure you of optimum performance and reliability, this amplifier has passed our rigorous
final inspection and listening test by the Icon Audio team in Leicester . During which the final set
up and adjustments were made.
Date
…./…./….
Model
……….
Amp Serial Number
……….
Customer
……………………………
Check amplifier finish
……….
Internal wiring check
……….
Check Triode mode
……….
Run min 6 hour test
……….
Check inputs & tape monitor
……….
Output Valve Bias level
……mv
Sound
Quality ……….
Channel
Balance
……….
Valve
Microphony
……….
Valve
Seating ……….
Hum level left/right
...../…..mv
RF
Test
……….
LED
brightness
……….
Serial No sticker and recorded
……….
Mains voltage
110 / 240V
IEC Mains Fuse
………A
Soft Start Fitted
……….
Sales
invoice
……….
Bottom
label
……….
Credit card receipt
.………
Customer survey form
.………
Bias
meter
……….
Transformer Protection
……….
Upgrades:
Phono
pre-amp
……….
HT delay required?
…Y / N
Output
valves ……….
1
st
Stage valve
……….
Phase splitter valve
……….
Triode conversion (ie vers only) ……….
Mains
lead
……….
Interconnects ……….
Signed
off
by
……………………….
Notes:
Please note we do not test the standard mains lead.