background image

Events

LED Indicators

LED

Signal

Function

LED 1

Green | Green Flashing

Communication Error | Communication OK

LED 2

Green | Green Flashing

Supply Sensor & Module OK | Undervoltage

LED 1 : Communication

LED 2 : Supply

Input Signal | Supply

Data Transmission Rate

COM2

Frame Rate

2.2

Minimal Cycle Time

3 ms

Process Data Cycles

3 ms @ minimal cycle time

Process Data Length

2 byte input

I-O Link Data

Process | Input Data

Byte 0

Byte 1

LSB

M

SB

Analog Current Converter

 

The measuring range from 0 – 21.15 mA will be shown in 16384 steps.

Class / Qualifier

Code (High + Low)

Mode

Type

Instance

Appears

Error

AL

Device 

Hardware

Supply

Supply low voltage

U2 =  

24V

0xC0

0x30

0x03

0x5000

0x010

0

0x0010

0x0002

0xF3

0x5112

Disappears

Error

AL

Device 

Hardware

Supply

Supply low voltage

U2 =  

24V

0x80

0x30

0x03

0x5000

0x010

0

0x0010

0x0002

0xB3

0x5112

LinkPro

® 

IO Adapter

4

23-0149

Reviews: