19
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damag-
ing the console, keep liquids away from the
console and keep the console out of direct sun-
light.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in. If lines appear in the
console display, see HOW TO USE THE INFORMA-
TION MODE on page 18 and adjust the contrast level
of the display.
If the console does not display your heart rate when
you hold the handgrip pulse sensor, or if the displayed
heart rate appears to be too high or too low, see step
5 on page 16.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press
and hold the Target Toning Workouts button for sev-
eral seconds until the calibration mode appears in the
display.
Press the Target Toning Workouts once. The ramp cal-
ibration instructions will appear in the display. Press
the 1 Step Power Ramp Increase or Decrease button
to calibrate the ramp. The ramp will move upward and
downward as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Target Toning Workouts button repeat-
edly to exit the calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed switch, first unplug the power cord.
Using a flat screwdriver, release the tabs on the
Access Cover (20) and pull the Access Cover upward
off the elliptical.
Next, look into the access opening and locate the
Reed Switch (69). Rotate the Large Pulley (74) until a
Pulley Magnet (75) is aligned with the Reed Switch.
Next, loosen, but do not remove, the indicated M4 x
16mm Screw (106). Slide the Reed Switch (69)
slightly toward or away from the Pulley Magnet (75).
Then, retighten the M4 x 16mm Screw.
Plug in the power cord and rotate the large pulley for a
moment. Repeat these actions until the console dis-
plays correct feedback. When the reed switch is
correctly adjusted, reattach the access cover.
MAINTENANCE AND TROUBLESHOOTING
20
74
69
106
75