Absolute Maximum Ratings.
Under no circumstances must the absolute maximum ratings giving in this table be violated. Stress
exceeding one or more of the limiting values may cause permanent damage to the device.
Parameter
Min
Max
Units Condition
Charger Supply Voltage
4.5
6.3
V
Users must utilize an iControl provided
charging cradle for the iSCAN
™.
Polarity
protected. Onboard LI controller.
Voltage on any digital pin
-0.3
3.6
V
N/A
Input RF level
10
dBm
Storage temperature range
-50
150
C
Operating ambient temperature
-20
50
C
Figure 3 Maximum Ratings