16

iCool Lite

engineered ways to ensure that no matter what happens in the field, in most cases you can still use your iCool for that important event. Realistically, 

even the best electronic systems occasionally have problems, especially in portable systems that have a relatively hard life and where water and 

heat are involved. Fortunately, we have very few such problems, but as an added benefit we have built into all iCool’s a complete manual override 

system that allows your iCool to operate effectively even if the touch screen is damaged.

We do not publish this over ride information in the manual because it is a little different from model to model, but in the rare event that you ever 
have a failure of the touch screen which prevents you from operating your iCool, just call or e-mail the local iCool representative in your country, or 

our international number or go to our web site and we will give you instructions on how to use the manual over ride facility on your particular model. 

At www.iCoolSport.com you will find a listing of representatives around the world, or you can request a reply  directly from our factory in Australia. 
You will be contacted promptly and we will explain how to work around your problem until we can arrange repairs.  This is an important service that 

we hope you never need, but it’s good to know it is there. In addition to this service you will be pleased to know that your iCool is of a modern modular 

design, which means that most components can be easily replaced in the field and often by the owner.

UNDERSTANDING THE HEATING MODE PROTECTION CIRCUIT

For safety reasons you can only initiate the heating mode at the time the unit is first switched on. You can not change to heating while you are using 
it in the cooling mode. You must switch off at the main switch first.

With TWIN models both heat pumps can cool at the same time or one can heat and one can cool at the same time.

You must use a pool cover when heating the water.

We all understand heat rises and so you must use a cover on top of your pool when heating or you will lose a large amount of the heat energy into 

the room and it will take much longer to heat the water.

If the status bar lights turn red when you start a cooling cycle.

It means you have inadvertently selected a temperature that is higher than the current pool water temperature. Switch off at the main power switch 

to reset the computers and start again, this time set a temperature that is LOWER than the current pool temperature. Once the iCool is operating in 

the cooling mode you can then change your selected temperature to any temperature, even one that is higher than the current water temperature 
and is will still stay in the cooling mode. This is useful if the early morning pool temperature is already lower than you require but you want the iCool 
to prevent the water rising above your desired temperature as the day warms up.

Summary of Contents for COMPACT Cool

Page 1: ...Owners Manual iCool Lite ...

Page 2: ......

Page 3: ...armful to athletes Because of the very small size the Lite uses a very compact stainless steel heat exchanger with silver connection seams Chlorine and Bromide are very corrosive and can quickly cause serious damage to stainless steel and silver If you must use corrosive chemicals such as chlorine or salt water then you must use any of the larger iCool models All of our bigger iCools have titanium...

Page 4: ...od insulation reduces these losses Good insulation will result in much faster cooling and save a lot of electricity HOLDING THE SET TEMPERATURE In normal conditions once your pool reaches your set temperature your iCool Lite has been designed to have enough cooling power to continue to hold that temperature even if several athletes are using the pool NEVER USE CORROSIVE CHEMICALS Bromide and Chlor...

Page 5: ...rcome this quickly and easily ABOUT PUMPS Water flow through your iCool Lite is produced by a high quality long life circulating type pump that is fitted with a water filter to assist in keeping the water in your pool clean Circulating type pumps are not self priming they can lift and move water reliably for many thousands of hours but due to the long life design they can not provide suction to be...

Page 6: ...ter pump by plugging it directly in to a normal power outlet however you will need to activate the Disarm Flow Safety Sensor function to prevent your Lite shutting down due to a false No Water alarm explanation in next paragraph Also the water flow sensor can be permanently disarmed by a small wiring change Full details of both options can be found under Support Technical on the iCool website Look...

Page 7: ...nd Lite models CONNECT THIS HOSE TO THE TOP OF YOUR POOL THIS HOSE SENDS THE CHILLED OR HEATED WATER BACK TO YOUR POOL THIS HOSE COLLECTS WATER FROM YOUR POOL TO FEED IN THROUGH THE FILTER AND ON THE ICOOL TO BE CHILLED OR HEATED THIS HOSE SENDS FILTERED WATER TO THE ICOOL TO BE CHILLED OR HEATED FROM THE POOL TO THE FILTER PUMP FROM THE FILTER PUMP TO THE ICOOL FROM THE ICOOL BACK TO THE POOL HEA...

Page 8: ...and show a steady white light to indicate that the systems check was successful and that your iCool is ready to use Personal Logo Welcome Screens If you did not request a personal logo screen then the standard iCool WELCOME screen will appear Touch the welcome screen anywhere to continue The main operation screen will appear Your Lite is now ready to cool or heat if it is the dual temp model Main ...

Page 9: ...h to heating or cooling depending on the temperature you set at the time you first switch it on The water is then automatically cooled or heated to your preset temperature and kept at that temperature For safety reasons you can not switch between Cold and Hot modes while your Lite is operating To change the mode you must switch off the Water Temperature Setting Screen 10 22 WARNING WARNING It is e...

Page 10: ...by touching the change setting button this will take you to the change settings screen From here you proceed as described previously Note If you have the contrast model for safety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is required to reset the computer for safe monitor...

Page 11: ...renheit and the sound level from the screen Main Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to control the fan speed to give the very best efficiency and fastest cooling Quiet Mode If you are in a very quiet environment you can select QUIET MODE b...

Page 12: ...screen will begin to flash as with setting the clock Use the same up down and left right arrows to set the number of hours and minutes you wish to elapse before the system automatically shuts down The system automatically begins Time Setting Screen 11 25 TIMER FUNCTIONS SET MAIN CLOCK the countdown and will stop when the time you set reaches zero The time remaining before shutdown is displayed on ...

Page 13: ...ouching the display clock full screen button To go back to the previous screen touch the back 1 button Resets time to preset value in the single shot mode ready to start again by pressing the start button When this button is pressed the countdown will repeat until the repeat function is cancelled by pressing once again A red dot indicates that it is active DISPLAY CLOCK FULL SCREEN 14 10 2 10 14 1...

Page 14: ...overing the topic you need assistance with the screen will change to a series of pages covering that subject Sample screens are illustrated below You can flip forward or backwards from page to page using the buttons on the right hand side of the help screens or you can return to the main help menu page at any time If your screen locks up or displays random text while using the help menus please re...

Page 15: ...to normal when you restart it When your screen first starts up and the welcome screen appears a small warning notice may appear in the centre of the screen for one or two seconds referring to the inter computer communication requirements this is normal If this notice does not go away it means that data is not flowing to the screen This is usually because the data cable to the touch screen has come...

Page 16: ...ition to this service you will be pleased to know that your iCool is of a modern modular design which means that most components can be easily replaced in the field and often by the owner UNDERSTANDING THE HEATING MODE PROTECTION CIRCUIT For safety reasons you can only initiate the heating mode at the time the unit is first switched on You can not change to heating while you are using it in the co...

Page 17: ...erage 30 Litres per min average Maximum Alternative Pump Flow 100 Litres per min 500 Watts 100 Litres per min 500 Watts 150 Litres per min 750 Watts Main Power Plug 3 Pin Heavy Duty 3 Pin Heavy Duty 3 Pin Heavy Duty Weight KG Pounds 21kg 49Lbs 22kg 50Lbs 40kg 88Lbs Dimensions H W D in mm 240 x 420 x 300 240 x 420 x 300 545 x 475 x 290 Dimensions H W D in inches 10 x 16 5 x 11 8 10 x 16 5 x 11 8 21...

Page 18: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com ...

Reviews: