background image

04

iCool Lite

Your iCool Lite is smallest system available that can provide the full range of ice bath therapy temperatures in any single person iCool pool or any 
normal sized bathtub. It’s breakthrough technology packs the most cooling power possible in such a small space. The Lite is designed for either 

fixed position operation or for easy transportation to almost anywhere you need to provide ice bath recovery. 

To avoid damage it should always be transported in the purpose designed iCool military grade protective travel case, available as an option.

PERFORMANCE

Your iCool Lite has impressive performance for such a small system, but naturally it can not cool a pool as fast as our much larger iCools. You can 

expect cooling of at least 3 to 5 degrees C per hour in a single person pool and it may cool even faster depending on your basic setup and local 

conditions. The temperature in the operating area, the amount of water being cooled and the starting temperature of the water will all have some effect. 

FOR BEST PERFORMANCE

Operate in a well ventilated shaded area. Definitely not in direct sunlight

Use an insulated pool (all iCool pools are properly insulated)

Use an insulating matt under the pool to prevent loss of cold into the ground. (All iCool pools have built in insulating mat)

Use a pool cover. Most iCool pools include a cover.

When water is very cold the difference between the pool water and the room temperature is very large, so the cold can be quickly lost. Good 
insulation reduces these losses. Good insulation will result in much faster cooling and save a lot of electricity. 

HOLDING THE SET TEMPERATURE 

 

In normal conditions, once your pool reaches your set temperature your iCool Lite has been designed to have enough cooling power to continue to 
hold that temperature even if several athletes are using the pool.

NEVER USE CORROSIVE CHEMICALS 

Bromide and Chlorine can cause major long term damage even to the high grade stainless steel heat exchanger in your iCool and could eventually 

cause a total system failure that is not covered by your warranty. These chemicals eat away most metals and can also be harmful to athletes. This 

Model iCool has a stainless steel heat exchanger tank that must only be used with fresh clean water. To control bacteria, a small amount of mild 

bathroom type disinfectant gives the same result as chlorine and will not cause harm to your iCool. It is also much safer for athletes. 

Please also 

avoid the use of salt water to ensure long life of your system. 

For extended use of the same pool water, iCool includes a small light weight filtration system with your lite that allows extended multi athlete use. It 
is fully compatible with your Lite which includes a special electric shock protection power outlet to operate the filter pump safely.

POOL SETUP ADVICE

Before  you turn on your iCool system you must set up and fill the pool. iCool portable inflatable pools come with their own instructions and are easy 
to set up. Please be sure that the pool is in the position you require before you fill them with water as the weight of the water will make it impossible 
to move the pool once it is filled.

INTRODUCTION

Summary of Contents for COMPACT Cool

Page 1: ...Owners Manual iCool Lite ...

Page 2: ......

Page 3: ...armful to athletes Because of the very small size the Lite uses a very compact stainless steel heat exchanger with silver connection seams Chlorine and Bromide are very corrosive and can quickly cause serious damage to stainless steel and silver If you must use corrosive chemicals such as chlorine or salt water then you must use any of the larger iCool models All of our bigger iCools have titanium...

Page 4: ...od insulation reduces these losses Good insulation will result in much faster cooling and save a lot of electricity HOLDING THE SET TEMPERATURE In normal conditions once your pool reaches your set temperature your iCool Lite has been designed to have enough cooling power to continue to hold that temperature even if several athletes are using the pool NEVER USE CORROSIVE CHEMICALS Bromide and Chlor...

Page 5: ...rcome this quickly and easily ABOUT PUMPS Water flow through your iCool Lite is produced by a high quality long life circulating type pump that is fitted with a water filter to assist in keeping the water in your pool clean Circulating type pumps are not self priming they can lift and move water reliably for many thousands of hours but due to the long life design they can not provide suction to be...

Page 6: ...ter pump by plugging it directly in to a normal power outlet however you will need to activate the Disarm Flow Safety Sensor function to prevent your Lite shutting down due to a false No Water alarm explanation in next paragraph Also the water flow sensor can be permanently disarmed by a small wiring change Full details of both options can be found under Support Technical on the iCool website Look...

Page 7: ...nd Lite models CONNECT THIS HOSE TO THE TOP OF YOUR POOL THIS HOSE SENDS THE CHILLED OR HEATED WATER BACK TO YOUR POOL THIS HOSE COLLECTS WATER FROM YOUR POOL TO FEED IN THROUGH THE FILTER AND ON THE ICOOL TO BE CHILLED OR HEATED THIS HOSE SENDS FILTERED WATER TO THE ICOOL TO BE CHILLED OR HEATED FROM THE POOL TO THE FILTER PUMP FROM THE FILTER PUMP TO THE ICOOL FROM THE ICOOL BACK TO THE POOL HEA...

Page 8: ...and show a steady white light to indicate that the systems check was successful and that your iCool is ready to use Personal Logo Welcome Screens If you did not request a personal logo screen then the standard iCool WELCOME screen will appear Touch the welcome screen anywhere to continue The main operation screen will appear Your Lite is now ready to cool or heat if it is the dual temp model Main ...

Page 9: ...h to heating or cooling depending on the temperature you set at the time you first switch it on The water is then automatically cooled or heated to your preset temperature and kept at that temperature For safety reasons you can not switch between Cold and Hot modes while your Lite is operating To change the mode you must switch off the Water Temperature Setting Screen 10 22 WARNING WARNING It is e...

Page 10: ...by touching the change setting button this will take you to the change settings screen From here you proceed as described previously Note If you have the contrast model for safety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is required to reset the computer for safe monitor...

Page 11: ...renheit and the sound level from the screen Main Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to control the fan speed to give the very best efficiency and fastest cooling Quiet Mode If you are in a very quiet environment you can select QUIET MODE b...

Page 12: ...screen will begin to flash as with setting the clock Use the same up down and left right arrows to set the number of hours and minutes you wish to elapse before the system automatically shuts down The system automatically begins Time Setting Screen 11 25 TIMER FUNCTIONS SET MAIN CLOCK the countdown and will stop when the time you set reaches zero The time remaining before shutdown is displayed on ...

Page 13: ...ouching the display clock full screen button To go back to the previous screen touch the back 1 button Resets time to preset value in the single shot mode ready to start again by pressing the start button When this button is pressed the countdown will repeat until the repeat function is cancelled by pressing once again A red dot indicates that it is active DISPLAY CLOCK FULL SCREEN 14 10 2 10 14 1...

Page 14: ...overing the topic you need assistance with the screen will change to a series of pages covering that subject Sample screens are illustrated below You can flip forward or backwards from page to page using the buttons on the right hand side of the help screens or you can return to the main help menu page at any time If your screen locks up or displays random text while using the help menus please re...

Page 15: ...to normal when you restart it When your screen first starts up and the welcome screen appears a small warning notice may appear in the centre of the screen for one or two seconds referring to the inter computer communication requirements this is normal If this notice does not go away it means that data is not flowing to the screen This is usually because the data cable to the touch screen has come...

Page 16: ...ition to this service you will be pleased to know that your iCool is of a modern modular design which means that most components can be easily replaced in the field and often by the owner UNDERSTANDING THE HEATING MODE PROTECTION CIRCUIT For safety reasons you can only initiate the heating mode at the time the unit is first switched on You can not change to heating while you are using it in the co...

Page 17: ...erage 30 Litres per min average Maximum Alternative Pump Flow 100 Litres per min 500 Watts 100 Litres per min 500 Watts 150 Litres per min 750 Watts Main Power Plug 3 Pin Heavy Duty 3 Pin Heavy Duty 3 Pin Heavy Duty Weight KG Pounds 21kg 49Lbs 22kg 50Lbs 40kg 88Lbs Dimensions H W D in mm 240 x 420 x 300 240 x 420 x 300 545 x 475 x 290 Dimensions H W D in inches 10 x 16 5 x 11 8 10 x 16 5 x 11 8 21...

Page 18: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com ...

Reviews: