In the unlikely event that your system shuts itself down for any reason, you must identify and correct
the problem that has caused the safety system to operate before allowing anyone to use the iCool.
Never restart without identifying and correcting any fault.
Operating Issues
Compact Not Cooling or
Heating
Your iCool has several safety systems including one that
prevents the gas pressure reaching a dangerous high level.
This can only happen if the machine is extremely overheated.
If the machine has been operated in very hot conditions, in
a confined space or if the airflow has been blocked or partly
blocked for a certain amount of time, or if it’s placed too close
to a wall, towel, source of heat or other object, it may cause
the safety system to operate.
Damage resulting by any of those reasons will not be
covered under warranty.
Cold only models: If your chiller is running normally but hasn’t
changed temperatures after more than 45 minutes, please
make sure that the Target Temp is lower than the actual
pool temp. Cold only models do not have a heating capacity
therefore the temperature of the pool must be higher than the
pre-selected temperature.
If your Compact is not cooling or heating at all but seems to be
running correctly, it may most likely be out of refrigeration gas
and needs to be re-gassed. Re-gassing can be done by your
local refrigeration technician.
Once re-gassed, you must absolutely provide enough
ventilation to keep the machine within a safe operating
temperature.
“System Too Hot” Warning
Your Compact can move large amounts of heat per hour.
Naturally this heat has to be removed into the air surrounding
the system. The powerful fan can normally handle this with
ease, however if the air flow around the iCool is restricted so
that the heat can not escape, or the outside air temperature is
more than 45ºC, eventually the system will reach the limit of
it’s safe operating range. If the temperature inside the cabinet
reaches 70ºC the safety system will shut it down, sound an
alarm and display the warning screen.
Please make sure that the fan is turning on and the condenser
fins on the Compact are not covered or restricted and that the
area has a good flow of fresh air. On very hot days when the air
temperature is more than 45ºC it may not be possible to run
the system at full power due to the excessive heat.
Cooling a pool that has previously been heated can also cause
a heat overload warning and shut down. This will only occur
if the pool is still above 30-35ºC. It is good practice to allow
the heat to reduce naturally to below 30ºC before starting the
cooling cycle. This also saves a lot of electricity.
Software Not Loading
If the software doesn’t load for any reason, we recommend
turning the unit OFF and ON first to see if that solves the issue.
If the issue persists, please contact iCool Support.
Screen Freeze
This is a very rare issue. If the screen freezes while the iCool
is running normally, the main computer will usually still carry
on running the system and monitoring the safety features
but you will not be able to change anything and the displayed
temperatures will not update. You can either allow it to keep
running if that is more convenient, or you can restore the
system to normal operation by switching off the main power
and re starting again.
Remote Screen Not Connecting
If you’re operating via the optional 13” Remote Touch screen
and the screen does not connect to your chiller, make sure
that the data cable is correctly plugged to the chiller and to
the back of the screen. You can also try turning the unit OFF
and ON again and waiting for 30 seconds. The connection
should be automatic.
Wifi Issues
If you’re unable to operate your chiller via Wifi, this is most
likely due to a slow local Network or issues with your modem.
In that case, you will need to operate your chiller from its in-
built screen.
Water Leaks
Please note that your unit is a very powerful chiller and
condensation will occur inside of it. Water may leak at the
back of the chiller, this is completely normal. If necessary, you
can place a dripping tray under the unit to catch the overflow
water.
If leaks appear around fittings, unscrew fitting and add
Plumbing tape to help seal the connector - this is widely
available at any hardware store.
Safety Switch Tripping
If your unit is tripping the safety switch, please make sure you
are plugging the chiller to the same voltage noted on the side
of the chiller.
If that is correct, please check at what stage of the Progress
Bar the unit trips.
1
If the chiller trips when the pump starts
--> Check pump connection
2
If the chiller trips when the compressor motor starts
--> Please contact iCool Support
3
If the chiller trips when the fan starts
--> Please contact iCool Support
Summary of Contents for 4 Series
Page 1: ...Series 4 Owner s Manual Compact Range www icoolsport com support icoolsport com ...
Page 9: ...Get Started O3 ...
Page 15: ...TechnicalSupport O5 ...
Page 19: ......