background image

9

8

Specifications

MODEL

COOL

COOL Dual Temp

XP

XP Dual Temp

ICEMAN

Power

  Line Voltage

  Cooling / Heating

  Running Power 220V (& Max.)

  Running Power 110V (& Max.)

  Frequency 110V / 220V

Manufactured in 110V or 220V

5000 Watts / Chill Only

5 Amps (12 Amps)

10 Amps (20 Amps)

50/60Hz

Manufactured in 110V or 220V

5000 Watts / 5000 Watts

6.5 Amps (13 Amps)

13 Amps (26 Amps)

50/60Hz

Manufactured in 110V or 220V

7200 Watts / Chill Only

7.5 Amps (14 Amps)

14 Amps (28 Amps)

50/60Hz

Manufactured in 110V or 220V

7200 Watts / 7100 Watts

7.5 Amps (14 Amps)

15 Amps (28 Amps)

50/60Hz

Manufactured in 110V or 220V

7800 Watts / Chill Only

7.5 Amps (14 Amps)

14 Amps (28 Amps)

50/60Hz

Finishes & Materials

  Cabinet & Chassis & Coatings

  Heat Exchanger

  Heat Pump Pumbing

  Handles / Wheels /  Side Panels

Marine Grade Aluminium - Blaze Blue

Titanium

Commercial Grade Copper 

St. Steel / Polyurethane / Co Extruded Acrylic

Marine Grade Aluminium - Blaze Blue

Titanium

Commercial Grade Copper 

St. Steel / Polyurethane / Co Extruded Acrylic

Marine Grade Aluminium - Blaze Blue

Titanium

Commercial Grade Copper 

St. Steel / Polyurethane / Co Extruded Acrylic

Marine Grade Aluminium - Blaze Blue

Titanium

Commercial Grade Copper 

St. Steel / Polyurethane / Co Extruded Acrylic

Marine Grade Aluminium - High Gloss Black

Titanium

Commercial Grade Copper 

St. Steel / Polyurethane / Co Extruded Acrylic

Size & Weight

  Net Height x Width x Depth in mm

  Net Weight Kg / Pounds

  Size & Weight in STANDARD SHIPPING (LxWxH)

  Size & Weight in TRAVEL CASE (LxWxH)

650 x 550 x 350 mm

32 Kg / 72 Lbs

650 x 460 x 840 mm 45 Kg

880 x 490 x 830 mm 52Kg 

650 x 55 x 35 mm

36 Kg / 79 Lbs

650 x 460 x 840 mm 49 Kg

880 x 490 x 830 mm 57Kg 

650 x 55 x 35 mm

39 Kg / 85 Lbs

650 x 460 x 840 mm 52 Kg

880 x 490 x 830 mm 60 Kg 

650 x 55 x 35 mm

39 Kg / 85 Lbs

650 x 460 x 840 mm 52 Kg

880 x 490 x 830 mm 60 Kg 

650 x 55 x 35 mm

39 Kg / 85 Lbs

650 x 460 x 840 mm 52 Kg

880 x 490 x 830 mm 60 Kg 

Pool Compatibility & Recommended Pool

Max. 500L pool / IceOne Pro

Max. 500L pool / IceOne Pro

Max. 2000L pool / IceMate Pro

Max. 2000L pool / IceMate Pro

Max. 2000L pool / IceMan Pro

Operation

  Lowest Temp / Highest Temp 

  Automatic operation

  24/7 operation

5ºC (40ºF) / No heating 

Yes

Yes

5ºC (40ºF) / 40ºC (104ºF)

Yes

Yes

5ºC (40ºF) / No heating 

Yes 

Yes

5ºC (40ºF) / 40ºC (104ºF)

Yes

Yes

2ºC (35ºF) / No heating

Yes

Yes

Display

  Software-chip

  Display

  Remote Control Screen

  Remote Control over WiFi

Developed by iCool

Full HD Capacitive Touch Screen

Optional

Yes

Developed by iCool

Full HD Capacitive Touch Screen

Optional

Yes

Developed by iCool

Full HD Capacitive Touch Screen

Optional

Yes

Developed by iCool

Full HD Capacitive Touch Screen

Optional

Yes

Developed by iCool

Full HD Capacitive Touch Screen

Optional

Yes

Electrical

  Earth Leak Device for maximum user safety

  Power Plug 3 pin UK, US, AUS, EU

  Airflow

  Sound

  Heat Pump Type

  RCD Pump

Yes 30 Milliamps max allowed leakage

3 Pin Heavy Duty to suit country

Low Noise - 2000 Cubic ft per minute

59 dBa tested at 1.5m

Rotary

Electrically Isolated Pump supplied by built-in 

RCD electrical safety device

Yes 30 Milliamps max allowed leakage

3 Pin Heavy Duty to suit country

Low Noise - 2000 Cubic ft per minute

59 dBa tested at 1.5m

Rotary

Electrically Isolated Pump supplied by built-in 

RCD electrical safety device

Yes 30 Milliamps max allowed leakage

3 Pin Heavy Duty to suit country

Low Noise - 3000 Cubic ft per minute

69 dBa tested at 1.5m

Rotary

Electrically Isolated Pump supplied by built-in 

RCD electrical safety device

Yes 30 Milliamps max allowed leakage

3 Pin Heavy Duty to suit country

Low Noise - 3000 Cubic ft per minute

69 dBa tested at 1.5m

Rotary

Electrically Isolated Pump supplied by 

built-in RCD electrical safety device

Yes 30 Milliamps max allowed leakage

3 Pin Heavy Duty to suit country

Low Noise - 3000 Cubic ft per minute

69 dBa tested at 1.5m

Rotary

Electrically Isolated Pump supplied by built-in 

RCD electrical safety device

Summary of Contents for 4 Series

Page 1: ...Series 4 Owner s Manual Compact Range www icoolsport com support icoolsport com ...

Page 2: ...O1 Your Compact O2 Quick Set Up O3 Get Started O4 Safety Procedures O5 Technical Support Table of contents ...

Page 3: ...the Compact Range has been designed with improved performance and latest technology in cooling and heating power Today s iCools are the most powerful mobile ice bath machines on the market to give you the fastest chilling performance available anywhere Manufactured from the highest quality materials and components for long service life ice bath sessions are quick to set up easy to use easy to pack...

Page 4: ...luded with your Compact Full HD Capacitive Touch Screen built in Complete Hose Set 18mm x 3000mm red or light green 12mm x 3000mm dark green 18mm x 500mm red or light green Industrial Water Pump with fittings to match the voltage of your machine 220V Yellow Davey Pump 110V Red Marlin Pump Standard pool fittings to suit 19mm 1 pool connections Power plug to suit country EU USA AUS or UK Owner s Man...

Page 5: ...40 mm 52 Kg 880 x 490 x 830 mm 60 Kg Pool Compatibility Recommended Pool Max 500L pool IceOne Pro Max 500L pool IceOne Pro Max 2000L pool IceMate Pro Max 2000L pool IceMate Pro Max 2000L pool IceMan Pro Operation Lowest Temp Highest Temp Automatic operation 24 7 operation 5ºC 40ºF No heating Yes Yes 5ºC 40ºF 40ºC 104ºF Yes Yes 5ºC 40ºF No heating Yes Yes 5ºC 40ºF 40ºC 104ºF Yes Yes 2ºC 35ºF No hea...

Page 6: ...ration may result in equipment damage not covered by warranty Prepare for set up Positioning Your Compact unit must be placed on a uniformly flat and level surface It should not be placed more than 30 meters from your pool Be sure to place the pool and chiller on an area that can support the weight of the bath when full water is very heavy 1KG per Litre It is always recommended that you seek the a...

Page 7: ...l IcePro inflatable bath IcePod Ball valve included with your chiller if ordered with an IcePro or IcePod tub This valve must be connected to the bottom of your pool and the longer hose with RED connectors set to open position while chiller is ON With the IcePro inflatable baths make sure to inflate the pool prior to connecting the hoses iCool MiPod Remote Fiberglass bath With a MiPod Remote your ...

Page 8: ...ocket If not using the water pump provided do not use pumps exceeding 1 000 w If your model is 220V please follow connections shown below for 220V Davey Pump If your model is 110V please follow connections shown below for 110V International Marlin Pump Compact Series 4 Water Pump Power On Off Main Power Main Power Switch Press T to test Safety Function Ethernet Voltage 220 Volts Water Pump Power W...

Page 9: ...Get Started O3 ...

Page 10: ...pump is running and the automatic start up procedure is in progress If everything runs correctly it will say Water flow started 2 Starting System after a few seconds the refrigeration compressor motor will start This sound is easily recognisable If everything runs correctly it will say System started 3 Introducing Air Flow after a few more seconds the main airflow fan will start 4 Starting System ...

Page 11: ...our iCool Compact has a built in SESSION TIMER Touch the blue MENU button to reveal all available options on your machine choose TIMER from the list This timer does not affect the operation of the chiller and will not switch it on or off This timer only allows you to set an alarm for the amount of time you want to remain in the pool It provides a count down on the screen and sounds a warning sound...

Page 12: ...cessful Your network name will be visible in the middle of your screen To change your connection simply tap the network name to reconfigure your settings Step 6 Click on the Main Menu and choose INFO An IP address will appear in the bottom right label as pictured To control your chiller remotely you will need to copy this IP Address onto any web browser on your smartphone tablet or computer Step 7...

Page 13: ...function Make sure all operators and users know where the ORANGE button is to remove all power This button is located on the Main Power Switch ELECTRIC SHOCK PROTECTION LIMITATIONS All iCool machines have built in electrical safety residual earth leakage protection systems It can only protect against devices actually connected to the iCool including the water pump It can not protect against faults...

Page 14: ...n ambient conditions and water volume If the heat exchange tank freezes the IceMan may stop to protects against damage from expanding ice Special care is required using the IceMan mode such cold temperatures can be dangerous and we advise supervision by another person as a sensible precaution It is recommended to clean your Compact often to avoid rust and dust building up and reducing performance ...

Page 15: ...TechnicalSupport O5 ...

Page 16: ...ter valve in your pool or elsewhere in the pipes please make sure the valve is in the OPEN position and water can flow properly Disconnect all hoses one by one and reconnect again Water flow can sometimes be restricted by foreign objects such as band aids or bits of clothing Disconnect reconnect GREEN and RED fittings from the Compact You may find some debris or items blocking the water flow Disco...

Page 17: ...ay not be possible to run the system at full power due to the excessive heat Cooling a pool that has previously been heated can also cause a heat overload warning and shut down This will only occur if the pool is still above 30 35ºC It is good practice to allow the heat to reduce naturally to below 30ºC before starting the cooling cycle This also saves a lot of electricity Software Not Loading If ...

Page 18: ...t Team at support icoolsport com Please allow up to 72 hours for us to get back to you due to time zone difference but we will of course get back to you much sooner in most cases iCool certified Repairs To get iCool certified repairs from our iCool Head Office in QLD Australia simply send your product to us and we ll assess the issue for you Cost All freight costs will be at your charge except ret...

Page 19: ......

Reviews: