background image

 

 

26 

 

5. Please store in a dry location, keeping the device free from lint and dust to keep the device 
clean and clear from blockage. 

6. Please keep the device out of direct sunlight to keep the device away from any unnecessary 
exposure to heat and light. 
 
No additional maintenance or service required. 

Technical Specification 

Gas Measured 

Carbon Monoxide (CO) 

Detection principle 

Electrochemical  

Concentration range 

0-100 ppm  

Monitoring resolution 

1 ppm  

Monitoring accuracy 

±≤

3 ppm/

±≤

10% of reading* 

Monitoring repeatability 

±≤

3 ppm/5% (within 120 sec)* 

Operating lifetime 

500 breath tests/12 months** 

Display 

Via the iCOquit mobile application 

Battery Life 

12 months and battery is non-replaceable 

Power 

3v Lithium-ion coin cell 

T

90 

response time  

<30 Seconds 

Operating temperature 

15 – 35

o

Storage/Transport Temperature 

0 – 50

o

Operating & Storage/Transport Humidity 

10 – 90% RH non-condensing 

Operating & Storage/Transport Pressure  

912.0 – 1114.0 mbar 

Dimensions 

Less than 150mm long x 30mm diameter 

Weight 

Less than 100g 

Materials 

Plastic casing: ABS and Polycarbonate  

H

2

 Cross Sensitivity 

6%

erating lifetime

 

Time required to warm/cool from the 

minimum/maximum storage temperature 

before use 

15 minutes 

*whichever is greater 

** whichever occurs first 

 

 

Summary of Contents for Smokerlyzer

Page 1: ...User Manual iCOquit Smokerlyzer...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...ll damage the carbon monoxide sensor inside the iCOquit CAUTION Do not use hand sanitising products containing alcohol when using the device as this may damage the sensors CAUTION Use of accessories n...

Page 6: ...stallation and Set up 4 User Interface 5 Using the iCOquit 8 Connecting to the iCOquit 14 Completing a Breath Test 15 Interpreting Breath Test Result 17 Smoking Habits Questions 18 Navigation Drawer M...

Page 7: ...should be washed regularly in accordance with infection control practice 2 Please do not attempt to modify the equipment in any way or use accessories not specified by the manufacturer Any attempt to...

Page 8: ...can be used in smoking cessation programmes Instrument Layout 1 Breath sample port 2 On pairing button 3 LED light ring pairing light 4 Information label including serial number 5 Breath exhaust Insta...

Page 9: ...ithin the iCOquit app The device automatically disconnects after 10 seconds of inactivity or when a breath test is complete User Interface Splash Screen The splash screen shall display upon starting t...

Page 10: ...mail Address field 2 Password field 3 Forgotten Password button starts a new forgotten password process 4 Sign In Button starts the authentication process 5 Register button starts the user registratio...

Page 11: ...scription 3 The second dashboard shows days until quit date or if quit date has been reached it will show number of days smoke free 4 The last dashboard shows amount of money user has saved 5 Results...

Page 12: ...utton b If the user is already a user but has forgotten their authentication credentials the user will need to tap the Forgotten Password Button c If the user is not currently a registered user they w...

Page 13: ...order to reset password The user will then need to tap the continue button 3 The last step is to provide a new password and rewrite that password and then tap the submit button After the new password...

Page 14: ...to tap the Update Button 2 The second part of the registration process is providing the users smoking habits This will involve a Providing the number of cigarettes smoked per day b Providing the cost...

Page 15: ...on 1 The user will then be navigated back to the sign in screen The user must wait for their confirmation email before attempting authentication The user must tap the link in the email to confirm thei...

Page 16: ...oard provides an overview of the users smoking cessation progress b To start a new breath test tap the Breath test Button The breath test tab will display the hygiene warning and allow the user to sta...

Page 17: ...view historic breath test results the user will need to tap the Results button The results are in date order with the latest reading displayed from the left and oldest reading displayed furthest to r...

Page 18: ...etooth scanning phase will show a spinner while searching for a device 2 If an iCOquit device has been found and successfully connected to a tick shall be shown to indicate a successful connection bet...

Page 19: ...nect a retry icon shall appear indicating connection has failed but tap the icon to try again Completing a Breath Test Breath Test Initialisation 1 The first screen prompts the user to initiate the br...

Page 20: ...e a deep breath Hold Instructions 3 As prompted onscreen hold your breath until the countdown timer has finished 4 If the 15 second inhalation countdown is unattainable begin exhaling when ready and t...

Page 21: ...etation chart a Green Low CO PPM Reading b Yellow Moderate CO PPM Reading c Red High CO PPM Reading Once a breath test has been completed the user will be navigated to this screen where they will see...

Page 22: ...The user will need to complete the input fields relating to their smoking habits This will involve a Confirming whether they are still an active smoker b Providing how many cigarettes they are activel...

Page 23: ...ld tap the Continue Button 2 Once the answers have been provided and the user has tapped the Continue button they will be provided with a result which informs them of their smoking status There are fo...

Page 24: ...d b Manage Profile c iCOquit Smokerlyzer d Frequently Asked Questions e iCOquit Manual f About iCOquit g Delete Account h Sign Out Edit Personal Details 1 A user can navigate away by tapping the back...

Page 25: ...upon navigating to this screen 1 A user can navigate away by tapping the back button symbol 2 Upon successfully navigating to the device details screen device details about the connected device will a...

Page 26: ...Questions 1 The user can navigate away from the page by tapping the back button symbol 2 Upon navigating to the page a web view will appear which will display the iCOquit support web page The user wil...

Page 27: ...by tapping the back button symbol 2 Upon navigating to the page the user will need to the Delete Account Button to confirm they want to delete their account 3 The user will then be presented with a d...

Page 28: ...he back button symbol 2 Upon navigating to sign out a dialog will appear If the user taps yes this sign the user out and navigate them to the authentication page else if they tap No the user will be n...

Page 29: ...om VOCs for 24hrs What if I can t hold my breath for the recommended 15 second breath hold time Bedfont recommends that if you are unable to hold your breath for the recommended 15 seconds to hold you...

Page 30: ...y 3 ppm 5 within 120 sec Operating lifetime 500 breath tests 12 months Display Via the iCOquit mobile application Battery Life 12 months and battery is non replaceable Power 3v Lithium ion coin cell T...

Page 31: ...of safety application in the presence of a flammable anaesthetic mixture with air oxygen or nitrous oxide Equipment not suitable for use in the presence of flammable mixtures Refer to manual Serial N...

Page 32: ...ny other wireless equipment The iCOquit Smokerlyzer complies with the Medical Device Directive 93 42 EEC as amended by 2007 47 EC and the Medical Device Electromagnetic Compatibility standard IEC 6060...

Page 33: ...ic immunity The iCOquit is intended for use in the electromagnetic environment specified below The customer or the user of the iCOquit should ensure that it is used in such an environment Immunity tes...

Page 34: ...quipment should be moved Use of accessories transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or d...

Page 35: ...warranty is automatically invalidated if the product is repaired altered labels removed or otherwise tampered with by unauthorised personnel or have been subject to misuse neglect or accident Disposa...

Page 36: ...Ltd Station Road Harrietsham Maidstone Kent ME17 1JA England Tel 44 0 1622 851122 Fax 44 0 1622 854860 Email ask bedfont com Web www bedfont com Bedfont GmbH Mitterbachweg 18 5081 Anif Austria Tel 43...