Communication Test 

As the ZigBee network is controlled by the ZigBee coordinator, the 

ZT-2550/ZT-2570 (ZigBee coordinator) must be configured first. Please 
refer to documents shown below for full details of how to configure these 
devices. 

Once configuration of the ZigBee coordinator has been completed. 

Set the ”Pan ID” and the “RF Channel” values for the DL-100TMS-ZT 
to the same values as the network, and then reboot the device. The 
module will automatically start to function on the ZigBee network 
using the default protocol. 

 Documents 

 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-255x/

 

 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-257x/

 

 Configuration Utility 

(Used to configure ZT-2000 I/O device Coordinator) 

 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/utility/

 

Summary of Contents for DL-100TM-ZT

Page 1: ...uickStart v1 0 June 2020 Without Quick Start The package includes the following items DL 100TMS ZT Technical Support Product Website DataSheet Manual Tool http www icpdas com root product solutions re...

Page 2: ...MHz 2405 2410 2480 RF channels 0x04 0x09 0x0E or 0x0F are recommended because they do not overlap with the Wi Fi frequencies based 2 Preparation 1 Before you use this Utility please make sure you have...

Page 3: ...been completed Set the Pan ID and the RF Channel values for the DL 100TMS ZT to the same values as the network and then reboot the device The module will automatically start to function on the ZigBee...

Page 4: ...e serial port Clicking either the Connection Disconnect menu option or the icon will disconnect the connection between the PC and the DL 100TMS ZT Clicking either the Functions Get Records menu option...

Page 5: ...dress will be 01 Click the OK button to connect to the DL 100TMS ZT Note The LCD will also indicate the module address 3 If a connection is successfully established the Utility will return to the prev...

Page 6: ...PC and the DL 100TMS ZT you can retrieve log data via the Utility software The procedure is as follows 1 Either click the Functions Get Records menu option or the icon and the Load Log Data window wi...

Page 7: ...on The Configuration window will then be displayed showing the current configuration of the module If any of the values are changed click the Set button to update the configuration of the module 2 Whe...

Reviews: