Connecting to the DL-100TMS-ZT Module 

1. 

Clicking either the “Connection->Connect->RS-232/RS-485” menu 
option or the “

” button will open the connection selection menu, as 

shown below: 

 

2.  Select your COM port number and set the Model Name selection to 

the DL-100TMS-ZT. If you are connecting to a new module, the 
default address will be 

01. Click the “OK” button to connect to the DL-

100TMS-ZT.

 Note: The LCD will also indicate the module address

.

 

3.  If a connection is successfully established, the Utility will return to the 

previous window and the message “Connection is established” will 
be displayed in the status bar. The 

” and “ 

 

” icons will also 

become available. 

4.  If you want retrieve records that are stored on the DL-

100TMS-ZT, click either the 

” icon or the 

“Functions->Get Records” menu option . 

5.  If you want to configure the DL-100TMS-ZT, either click the 

“ 

 

” icon or “Functions->Configuration” menu option. 

Summary of Contents for DL-100TM-ZT

Page 1: ...uickStart v1 0 June 2020 Without Quick Start The package includes the following items DL 100TMS ZT Technical Support Product Website DataSheet Manual Tool http www icpdas com root product solutions re...

Page 2: ...MHz 2405 2410 2480 RF channels 0x04 0x09 0x0E or 0x0F are recommended because they do not overlap with the Wi Fi frequencies based 2 Preparation 1 Before you use this Utility please make sure you have...

Page 3: ...been completed Set the Pan ID and the RF Channel values for the DL 100TMS ZT to the same values as the network and then reboot the device The module will automatically start to function on the ZigBee...

Page 4: ...e serial port Clicking either the Connection Disconnect menu option or the icon will disconnect the connection between the PC and the DL 100TMS ZT Clicking either the Functions Get Records menu option...

Page 5: ...dress will be 01 Click the OK button to connect to the DL 100TMS ZT Note The LCD will also indicate the module address 3 If a connection is successfully established the Utility will return to the prev...

Page 6: ...PC and the DL 100TMS ZT you can retrieve log data via the Utility software The procedure is as follows 1 Either click the Functions Get Records menu option or the icon and the Load Log Data window wi...

Page 7: ...on The Configuration window will then be displayed showing the current configuration of the module If any of the values are changed click the Set button to update the configuration of the module 2 Whe...

Reviews: