Index
(hex)
Name
Description
Data type
Flags
Default
position
70n2:08
Set auto increment compare
value
The next compare
position will be
automatically
calculated by adding
the incremental value
to the current compare
position (70n2:07)
Disable the auto-
increment compare
function by setting
this parameter to
zero
INT32
RO
0
8.7 Configuration Data
Index 0x80n0 ENC Settings Ch.n
Index
(hex)
Name
Description
Data type
Flags Default
80n0:0
ENC Settings Ch.n
Encoder settings
UINT8
RO
0x0B
80n0:01 A signal polarity
Polarity of A input signal
DT0803EN01
RW
0x01
("Active high")
80n0:02 B signal polarity
Polarity of B input signal
DT0803EN01
RW
0x01
("Active high")
80n0:03 C signal polarity
Polarity of C input signal
DT0803EN01
RW
0x01
("Active high")
80n0:04 Extern latch signal
polarity
Polarity of extern latch
HR input signal
NOTE:
The trigger level for
extern latch can not be
set for each channel
individually. Both
channel need to be set
to the same trigger level.
DT0803EN01
RW
0x01
("Active high")
80n0:05 Extern latch mode
Extern latch setting:
Latch encoder counter
or
Reset encoder counter
DT0804EN01
RW
0x01
("Latch
encoder
counter ")
80n0:09 Counting mode
Counter mode selection:
CW/CCW,
Pulse/Direction,
DT0801EN08
RW
0x03
("Quadrant
counting
ICP DAS
Page
ECAT-2092T User Manual
Version 1.0
67