4.10

 

 Version 

Press "Version" in tool menu, and the window would show the version of Utility and 

firmware. 

 

Text field: 

(1)

 

Firmware version: show the version information of 

GT-540P-3GWA-OEM2’s firmware 

(2)

 

Utility version: show the version information of GT-540P-3GWA-OEM2’s 

utility 

Operation: 

Read: Read these information from GT-540P-3GWA-OEM2. 

 

 

Summary of Contents for GT-540P-3GWA-OEM2

Page 1: ...GT 540P 3GWA OEM2 user s manual v1 0 2013 10 Ver 1 0 GT 540P 3GWA OEM2 Intelligent 3G Remote Terminal Unit With GPS User s Manual v1 0 High Quality Industrial Data Acquisition and Control Products ...

Page 2: ...o change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use or for any infringements of patents or other rights of third parties resulting from its use Copyright Copyright 2013 by ICP DAS CO LTD All rights reserved worldwide Trademark The names used for identification only m...

Page 3: ...reset GT 540P 3GWA OEM2 17 2 8 Charge and discharge of Li Battery 17 3 Installing GT 540P 3GWA OEM2 Utility 18 3 1 Installing NET Framework 18 3 2 Installing GT 540P 3GWA OEM2 Utility 20 4 GT 540P 3GWA OEM2 Utility Operation 23 4 1 Main menu 24 4 2 Operation Language 26 4 3 Login 27 4 4 Main Parameters 30 4 5 Device Status 43 4 6 Device Time 44 4 7 Counter Value 45 4 8 DO control DI status AI valu...

Page 4: ...can also be stored in the SD card to become a remote data logger For another communication mode the GT 540P 3GWA OEM2 offers the e mail mode to transfer the data by e mail via 3G GPRS for users to choose The simple I O linkage function of the GT 540P 3GWA OEM2 can reach the real time control in the local field It also supports Li ion battery as another power source when the main power is failed te...

Page 5: ...gger or AI hi lo alarm In addition to improve the way of communication that can also reduce the AP effort z Transfer data by e mail Expect for the transferring data by the general communication with the M2M RTU center users can choose the e mail mode to send these data by e mail over 3G GPRS network in the fixed time z Modbus RTU device connectivity The GT 540P 3GWA OEM2 is built in Modbus RTU pro...

Page 6: ...pport data transferring by E mail z Local I O linkage function to make the simple local control z Support data logger in micro SD card Max 4 GB bytes z Support 3 7V Li ion Battery backup z Power supply 12VDC 24VDC 1 2 Software Architecture The M2M RTU center software with friendly Graphic interface is to manage the 3G GPRS RTU products easily Users can monitor the I O data and status of 3G GPRS RT...

Page 7: ...ter The M2M RTU Center provided by ICP DAS is a M2M Machine to Machine management software that has a strong core technology for handling data and lets the user save the trouble of dealing with large IO data For detail information and downloading the software please refer to http ftp icpdas com pub cd usbcd napdos m2m rtu rtu_center ...

Page 8: ... pub cd usbcd napdos m2m rtu m2m_rtu_win32_api OPC server for RTU series of ICP DAS NAPOPC M2M DA Server ICP DAS NAPOPC M2M DA Server is an OPC software package operated as an OPC driver of a HMI or SCADA system It provides seamless connection with 3G GPRS RTU products G 4500 RTU GT 540P 3GWA OEM2 from ICP DAS to SCADA system InduSoft Wonderware iFix Citec LabView and etc following OPC 1 0 OPC 2 0...

Page 9: ...l Version 1 0 2013 10 7 53 1 3 Applications z Earthquake and Landslide Alarm system z Hydrologic monitoring System z Vending machine automation system z Sewage flow monitoring system z Piped water monitoring system z Vehicle monitoring system Vehicle monitoring System ...

Page 10: ...GT 540P 3GWA OEM2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 8 53 Hydrologic monitoring System ...

Page 11: ...GT 540P 3GWA OEM2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 9 53 1 4 How to use GT 540P 3GWA OEM2 ...

Page 12: ... Digital Input Channels 4 Input Type Sink or Source Isolated channel with common power or ground Off Voltage Level 1V max On Voltage Level 3 5 30 VDC Isolated Voltage 3750Vrms Counters 6 16 Bit 5 40Hz Min Pulse Width 25ms Relay Channels 3 Type Form A SPST N O Operating Voltage Range 250 VAC 30 VDC Max Load Current 5 0A channel at 25 C Electrical Life Resistive load 5 A 250 VAC 50 000 ops 3 A 250 V...

Page 13: ...2 Sensitivity Tracking up to 159 dBm with external LNA Cold start up to 146 dBm with external LNA Acquisition Time Hot start Open Sky 2 s typical Cold start Open Sky 36 s typical Protocol Support GPRSC format NMEA 0183 version 3 01 Power Protection Reverse polarity protection Frame Ground Protection ESD Surge EFT Hi Pot Required Supply Voltage 12 VDC 24 VDC Mechanical Casing Plastic Flammability U...

Page 14: ... the appearance of GT 540P 3GWA OEM2 DI DO Terminal No Pin Assignment 01 DI0 02 DI1 03 DI2 DI 04 DI3 DI COM 05 DI COM N A 06 N A 07 RL0 COM RL0 08 RL0 NO 09 RL1 COM RL1 10 RL1 NO 11 RL2 COM RL2 12 RL2 NO 13 AIn AI 14 AIn COM Port Power Input Terminal No Pin Assignment Ground for COM 01 GND 02 RxD1 COM1 RS 232 03 TxD1 04 D COM2 RS 485 05 D 06 RST Reset 07 RST 08 DC VS Power Input 12VDC 24VDC 09 DC ...

Page 15: ...GT 540P 3GWA OEM2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 13 53 2 3 Dimensions ...

Page 16: ...GT 540P 3GWA OEM2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 14 53 2 4 DI DO Internal Structure and Wire Connection 1 DI Wire Connection 2 Relay Wire Connection ...

Page 17: ...he power is active The power is not active on off 3G Green The modem LED can indicate the status of 3G module Modem normal Modem fail GPRS Mode Blanking per 3 sec WCDMA Mode Twinkling twice per 3 sec Off or Blanking not 3 sec STA Orange System LED is to indicate if the GT 540P 3GWA OEM2 is normal or fail Condition External power Normal WCDMA GPRS Fail PIN code is wrong On Blanking per 1 sec Always...

Page 18: ...M card confirm it is OK by the mobile phone 3 Pin08 and Pin09 connect to the DC VS and DC GND of the power supply 4 Follow the section 2 4 to wire the I O connection 5 If you want to use the backup power please connect the Li battery to the GT 540P 3GWA OEM2 6 It is needed to wait for 30 50 seconds to search the GSM base and register to the ISP After finishing the process GT 540P 3GWA OEM2 would b...

Page 19: ...t CON1 6 to DC VS 2 Connect CON1 7 to DC GND 2 8 Charge and discharge of Li Battery If users apply the Li Battery on GT 540P 3GWA OEM2 the Li battery would be charged by the external power automatically When the external power is removed from GT 540P 3GWA OEM2 the power supplying to GT 540P 3GWA OEM2 is from Li Battery When the power is only from Li Battery the running time of the GT 540P 3GWA OEM...

Page 20: ...above to execute the GT 540P 3GWA OEM2 Utility in the PC If there has NET Framework 2 0 or above in the PC the section 3 1 can be omitted 3 1 Installing NET Framework Please download the NET Framework 2 0 on the Microsoft web site and install it The install figure is as follows 1 Press Next to the next step 2 Select the I accept the terms of the License Agreement and Install to the next step ...

Page 21: ...T 540P 3GWA OEM2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 19 53 3 The installation process would be going 4 After finishing the installation press Finish to exit the program ...

Page 22: ...ng GT 540P 3GWA OEM2 Utility Launch Install_GT 540P 3GWA OEM2_Utility_Vxxx exe xxx Version Number and the installation figure is as follows 1 Press Next to start the installation procedure 2 Select the installation path The default path is C Progrm Files GT 540P 3GWA OEM2 Utility Press Next to the next step ...

Page 23: ...M2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 21 53 3 Input the name shown in All Programs Press Next to the next step 4 After finishing the installation procedure press OK to the next step ...

Page 24: ...l v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 22 53 5 Press Finish to finish the installation procedure 6 Launch GT 540P 3GWA OEM2 Utility from the start menu StartÆAll ProgramsÆGT 540 UtilityÆGT 540P 3GWA OEM2 Utility ...

Page 25: ...se following steps 1 The STA LED is blanking There are 2 kinds of blanking in GT 540P 3GWA OEM2 STA LED Description Blanking per 1 sec Normal mode Blanking per 50 ms The pin code is wrong The login windows would show the field to input pin or PUK code 2 Confirm the RS232 connection between GT 540P 3GWA OEM2 and PC is correct Users can refer to the following figure 3 During the setting procedure th...

Page 26: ...nu item login would become logout and the GT 540P 3GWA OEM2 Utility would be operated normally Once the power is reset the login procedure needs to do again 3 Language GT 540P 3GWA OEM2 Utility only supports English interface 4 File There are import and export functions in File item The functions would be enabled when Main parameters window is open Export The function can export the parameters to ...

Page 27: ...eral devices status including microSD 3G GPRS GPS and Modbus RTU 3 Device time Display or set the RTC time of GT 540P 3GWA OEM2 in this item It is also can get the information of the last and next time of the return report in E mail mode 4 DO Control and DI AI status Display the status of I O and control the DO output 5 Counter Value Inquire and set the counter value 6 Version Inquire the versions...

Page 28: ... 3GWA OEM2 user s manual Version 1 0 2013 10 26 53 4 2 Operation Language GT 540P 3GWA OEM2 Utility only supports English version currently In the future the Traditional Chinese and Simplified Chinese will be supported from the language menu bar ...

Page 29: ...lease set the system time of GT 540P 3GWA OEM2 If the pin code in GT 540P 3GWA OEM2 is not correct the STA led would be blanking per 50 ms and GT 540P 3GWA OEM2 utility would ask for users to input Pin or PUK code 1 Asking for inputting PIN code If the PIN code is effective the Enter SIM PIN SIM PUK window would pop up as follows If the number of times for inputting the wrong PIN code is more than...

Page 30: ...GT 540P 3GWA OEM2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 28 53 ...

Page 31: ...e PUK code window would pop up as follows As the number of times for inputting the wrong PUK code is more than allowed number the SIM card would be ineffective forever Therefore it is important to input the correct PUK code If the PIN or PUK code is correct the STA led would blank per second Users can operate other function of GT 540P 3GWA OEM2 in this utility ...

Page 32: ...ard Number This text field can show or input the phone number of the plug in SIM card Range 0 20 characters Mode Operation mode 1 RTU mode In this mode GT 540P 3GWA OEM2 would transfer I O data local I O Modbus device and GPS data to the M2M RTU center by 3G GPRS connection periodically 2 E Mail mode Transfer I O data by the e mail attached file through 3G GPRS connection periodically Data Logger ...

Page 33: ...io service GPRS bearer service in the GSM mobile network The APN defines the type of service that is provided in the packet data connection You can get this APN by ISP Range 0 31 Characters GPRS User Name The setting is important factor when connecting to a GPRS network Check with your GPRS service provider for details Range 0 31 Characters GPRS User Password The setting is important factor when c...

Page 34: ...n this update time The based unit is second Range 0 999999 sec Heartbeat Period sec Set the heartbeat time interval When the GT 540P 3GWA OEM2 update time is too long to terminate the GPRS connection by ISP the heartbeat time will report smaller package to keep GPRS connection unit sec Range 0 999999 sec Note Some ISP companies would terminate the GPRS connection when the GPRS connection has any d...

Page 35: ... The secondary Domain name server IP 5 E mail Mode Item Description E mail Authority The GT 540P 3GWA OEM2 only support two way of authority to login e mail server 1 none No authority 2 auth long AUTH LONG Server User Name The user name to login to the e mail server Range 0 35 characters Server Password The password to login to the e mail server Range 0 35 characters E mail Subject The subject of ...

Page 36: ...fields Range 0 51 Characters 7 RS 485 Info Range 110 2500 KB Max size of one attached file KB The maximum size of the attached files in a e mail The suggestion size is 600 KBytes Range 100 1200 KB Report Period min The interval time to send the e mail Range 0 65535 min Report Base Time hour The first time of hour to send the e mail Range 0 23 hour Report Base Time min The first time of minute to s...

Page 37: ...NC The DI channel is normal close When the DI channel is open low it is the trigger signal in the system 4 DI Counter Set the DI channel as counter mode Triggered Hold Time sec This value represents the holding time of the DI signal for triggering the event The unit is second Range 0 65535 sec Return Hold Time sec When the trigger condition is activated it needs to keep the non trigger status to b...

Page 38: ...ble the DO linkage with DI channel 2 Time The DO output would keeping ON according to the DO on Time when DI is triggered 3 Input Status The DO channel output would be kept contiguously according to the time of the Return Hold Time when the DI returns to the non trigger status 2 DO Relay Item Description Cycle Time sec The time of a duty cycle for DO If it is 0 duty cycle function is disabled Rang...

Page 39: ...Triggered Hold Time sec This value represents the holding time of the AI signal for triggering the event The unit is second Range 0 65535 sec Return Hold Time sec When the trigger condition is activated it needs to keep the non trigger status to be triggered again according to the Return Hold Time The unit is second Range 0 65535 sec DO Channel The DO channel will be activated according to the AI ...

Page 40: ...ents the holding time of the AI signal for triggering the event The unit is second Range 0 65535 sec Return Hold Time sec When the trigger condition is activated it needs to keep the non trigger status to be triggered again according to the Return Hold Time The unit is second Range 0 65535 sec DO Channel The DO channel will be activated according to the AI alarm Channel 0 1 DO On Time sec The DO c...

Page 41: ...A OEM2 user s manual v1 0 GT 540P 3GWA OEM2 user s manual Version 1 0 2013 10 39 53 be kept according to the time of the Return Hold Time when the AI returns to the non trigger status The Conditions of AI Trigger ...

Page 42: ...ing these steps to add a Modbus device to the GT 540P 3GWA OEM2 1 Select Modbus Device in the left window and press the right button of the mouse as the following figure 2 Select Add Device to add a Modbus device 3 There are Modbus device of ICP DAS for users to select If the Modbus device connected to GT 540P 3GWA OEM2 is not in the list please select Customer item to add this Modbus device 2 Rem...

Page 43: ...dress of reading the DI value DO Channels The number of DO channels DO Address The start address of reading the DO value AI Channels The number of AI channel AI Address The start address of reading the AI value AI Format The format of AI value Custom modbus device only support 16 bits value AI Type AI type AO Channels The number of AO channels AO Address The start address of reading the AO value A...

Page 44: ...port Parameters This function would read these parameters from par and show in Main Parameters window When pressing Import Parameters button the following window would pop up Select the path and the file to finish the importing process 2 Export Parameters This function would export these parameters to the par file When pressing Export Parameters button the following window would pop up After selec...

Page 45: ...atus Shows the status of micro SD card OK normal Error abnormal 2 Free Size Byte The remainder space of SD card 2 GPRS 1 Status Shows the status of GPRS connection 2 Error Code This code is for the connection status 3 GPS 1 Status Shows the GPS function is enable or disable 2 Data The current GPRMC data of GPS 4 M 7016 M 7060 M7080B This field shows the status of Modbus device connected to the GT ...

Page 46: ...GT 540P 3GWA OEM2 2 E Mail Report Time This field show the next time to send the mail when mail mode is enabled If the time is changed the information would be updated 3 Last E Mail Report Time This field show the last time to send the mail when the mail mode is enabled Operation description 1 Set as Now Set the time of the GT 540P 3GWA OEM2 according to the time of PC 2 Set Set the time of the GT...

Page 47: ...ined counter value The maximum is 999999999 This field is enabled when DI is set as counter mode If users want to clear these counter values set 0 to these counter values Operation 1 Read Read the current counter value and alarm settings from GT 540P 3GWA OEM2 If the DI channel is not set as counter the counter value is 0 2 Set Value Change the counter value into GT 540P 3GWA OEM2 according to the...

Page 48: ... DO0 DO2 Gray the voltage logic is high Red the voltage logic is low 2 AI Value the AI current value 3 Gain Gain value It can calibrate the AI value 4 Offset Offset value It can calibrate the AI value Operation 1 Read Read back the status of DI DO and AI value from GT 540P 3GWA OEM2 2 DO0 DO2 ON Set the DO output on 3 DO0 DO2 OFF Set the DO output off 4 Duty Cycle START Start the operation of Duty...

Page 49: ...on 1 0 2013 10 47 53 4 9 GPRS GSM Signal Quality This window can show GSM signal strength Text field The strength is divided into 5 sections shown in percentage And the top left corner of the window can show the signal type Operation 1 Read Read the WCDMA GPRS signal strength ...

Page 50: ...s Version in tool menu and the window would show the version of Utility and firmware Text field 1 Firmware version show the version information of GT 540P 3GWA OEM2 s firmware 2 Utility version show the version information of GT 540P 3GWA OEM2 s utility Operation Read Read these information from GT 540P 3GWA OEM2 ...

Page 51: ... used to recover GT 540P 3GWA OEM2 as factory settings including password 1 Make sure the STA led is blanking per 1 sec 2 Select the Recover to Factory Settings 4 11 2 Reset GT 540P 3GWA OEM2 The function is used to reset GT 540P 3GWA OEM2 by software 1 Make sure STA led is blanking per 1 second 2 Select Reset GT 540 button to reset GT 540P 3GWA OEM2 4 11 3 Debug In this Debug mode users can test ...

Page 52: ...ation 1 Mail Test In the E mail mode click the button to send the E mail to the defined e mail address 2 Monitor This function can transfer the debug messages from GT 540P 3GWA OEM2 and show in the Window 3 Save message Save the debug messages as files 4 Clear Clear the information in the debug filed ...

Page 53: ...pe as counter 5 Disable Enable GPS 2 E Mail mode The current file of data logger is stored in the path of RUNTIME As arriving the time to send e mail the system would move the file to the path of UPLOAD and package the file as e mail file in the path of EMAIL The logger file would be stored in the path of LOGFILE When finishing sending E mail the E mail file would be deleted In this mode the timin...

Page 54: ... understand that Date CI0 CI1 DI2 DI3 DO0 DO1 DO2 AI0 Module M 7016 Addr DI0 DO0 20100520 175518 119 230 0 1 1 0 0 0 059 5 1 0 20100520 175519 119 230 0 1 1 0 0 0 058 5 1 0 DO1 DO2 DO3 AI0 AI1 AO0 Module M 7060 Addr DI0 DI1 DI2 DI3 DO0 0 0 0 0 033 0 671 1 500 5 1 0 0 0 1 0 0 0 0 034 0 671 1 500 5 1 0 0 0 1 DO1 DO2 DO3 Module M 7080B Addr DO0 DO1 CI0 CI1 0 0 0 1 0 0 655361 5961 0 0 0 1 0 0 655361 5...

Page 55: ...he antenna is connected correctly The antenna must be outside 4 Utility can not connect to GT 540P 3GWA OEM2 Confirm STA Led is flashing per second If no refer to Item 2 for trouble shooting Check the wire connection of COM ports in PC and the GT 540P 3GWA OEM2 is correct Check the com port of PC is normal 5 Counter function is error Check the wiring of DI channel Check the frequency of counter is...