GW-7553-B / GW-7553-M PROFIBUS/Modbus TCP Gateway User Manual
(Version 1.35, May/2017)
PAGE: 97
a. New Setting
:
Open a new IP setting.
b. Load from file
:
Load a IP setting from the file.
c. Load from device
:
Load a IP setting from the GW-7553-B / GW-
7553-M.
3. Safe Value Setting =>
a. New Setting
:
Open a new safe value setting.
b. Load from file
:
Load a safe value setting from the file.
c. Load from device
:
Load a safe value setting from the GW-7553-B /
GW-7553-M.
4. View =>
a. Space configuration in device
:
Display memory address configuration
of select module in the GW-7553-B / GW-7553-M.
b. Space configuration in PROFIBUS
:
Display memory address
configuration of select module in PROFIBUS Master station.
c. Space configuration in Modbus
:
Display memory address
configuration of select module in the Modbus.
5. Help =>
a. Get Firmware Version From Module
:
Show firmware version of the
GW-7553-B / GW-7553-M.
b. About Utility
:
Show about version of the utility.
5.2.2 COM Port settings
:
1. Port: COM1~COM8
2. Baud rate: 2400/4800/9600/19200/38400/57600/115200
3. Parity: None/Odd/Even
4. Data bit: 8 data bit
5. Stop bit: 1 stop bit
5.2.3 Module state
:
It can display the number of modules in the GW-7553-B / GW-7553-M and
display module parameters in the window of the module parameter by click the
module‟s icon.
5.2.4 Module parameters
:
Display module parameters of the GW-7553-B / GW-7553-M.