The following DIP switch statuses present the “Module Group ID” value.
Table 2-4 Group ID Description
Dip switch statuses
Group ID value
00
01
02
03
The following “Module Group ID” values of device A and B present these ID are in the
same group which can communicate with each other.
Table 2-5 Group of “Module Group ID”
Device A Group ID value
Device B Group ID value
00 00
01
01 or 03
02
02 or 03
03
01 or 02 or 03
For example, there are three CAN networks, Network A, Network B and Network C, and
each of them uses one I-2533CS. The Group IDs of the I-2533CSs are 1, 2, and 3
respectively. The Network A can exchange the data with Network C because the Group
IDs of the I-2533CSs are in the same group (the second rule in the above table). The
Network B can exchange the data with Network C, which follows the third rule in the
above table. The Network A can’t connect with the Network B because these two
I-2533CSs are not in the same group.
Note:
The I-2533CS-A and I-2533CS-B don’t support the Group function. When using the
I-2533CS-A and I-2533CS-B, the Group ID of them must be the same.