4.3.4. Configure Other Parameters
From the “Configuration Options” block, user can get the module CAN status (CAN
Bus status, Error counter, and buffer status), CAN Rx FPS(received CAN message
frame per second) and reset the module.
[Get CAN Status]
command:
<1>
“
CAN Status
” item:
0x: value in hexadecimal format.
Please refer to appendix 6.3 for “CAN Status” definition.
<2>
“
CAN Error Counter
” item:
0x: value in hexadecimal format.
Please refer to appendix 6.4 for “CAN Error Counter” definition.
<3>
“
CAN Buffer Status
” item:
0x: value in hexadecimal format.
Bit
Symbol Value
Description
0
RX
CAN receive software buffer status
0
Receive software buffer underrun
1
Receive software buffer overrun
1
TX
CAN transmit software buffer status
0
Transmit software buffer underrun
1
Transmit software buffer overrun
3:2
-
Reserved
4
EW
CAN Error Warning status.
0
Both error counters are below the Error_Warning limit of 96
1
At least one of error counter has reached the Error_Warning limit of
96