Local/Remote I/O Application 

 

 

 

Data Exchange: Ethernet & RS-485 

 

Through Ethernet: Ebus         

 Through RS-485: Fbus 

 

PAC to PAC

 

 
 
 
 
 

 

 

VIP Communication Security 

Set VIP (Very 
Important IP No.) 
for Modbus TCP/IP 
security.

     

 

 

Modbus Master   

   

 

(RTU, ASCII, RS-232/485/422) 

 

Max. 

COM Ports (COM1:RS-232 or COM2:RS-485 or 

COM3: if X-board is plugged in) 

 

Can link to Modbus PLC or M-7000 I/O or Modbus 
devices (Power meter, temperature controller, 
inverter…) 

 

 

Modbus RTU/TCP Slave Ports 

 

Modbus RTU (RS-232/485/422) :

 

max. 

2

 COM Ports 

 

Modbus TCP/IP: 

 

max.

 

4

 PC/HMI/SCADA connection 

 

 

 

Auto-report Acquisition Data & Control Data 

I-7188EG/EGD can use UDP/IP to auto-report acquisition data & control data to local or remote internet PC/Server.   

Advantage: Every I-7188EG/EGD in the different location doesn

’t need a fixed IP. 

 

http://

www.icpdas.com

 

2 of 4    [ I-7188EG/7188EGD ] 

 Hot-Swap 

 Auto-Configuration 

at run time 

 Plug & Play   

at run time 

 High profile I-87K 

only 

Many types 

for choices 

Summary of Contents for I-7188EG

Page 1: ...d COM Ports I Os or memories of I 7188EG I 7188EG supports Modbus serial protocol Modbus TCP IP protocol Modbus Master protocol Remote I O Fbus Ebus SMS Short Message Service modem link MMICON LCD and user defined protocol I 7188EGD is the same as I 7188EG but with 5 digit 7 segment LED display ISaGRAF PAC supports ISaGRAF Ver 3 Workbench 1 of 4 I 7188EG 7188EGD http www icpdas com Support IEC 611...

Page 2: ...dbus devices Power meter temperature controller inverter Modbus RTU TCP Slave Ports Modbus RTU RS 232 485 422 max 2 COM Ports Modbus TCP IP max 4 PC HMI SCADA connection Auto report Acquisition Data Control Data I 7188EG EGD can use UDP IP to auto report acquisition data control data to local or remote internet PC Server Advantage Every I 7188EG EGD in the different location doesn t need a fixed I...

Page 3: ...isplay RoHS 80188 40 MHz 10 Base T gray Accessories ISaGRAF 256 E ISaGRAF Workbench Software Ver 3 256 I O Tags with USB Dongle and English application book ISaGRAF 256 C ISaGRAF Workbench Software Ver 3 256 I O Tags with USB Dongle and Chinese application book ISaGRAF 32 E ISaGRAF Workbench Software Ver 3 32 I O Tags with English application book Note ISaGRAF 32 C ISaGRAF Workbench Software Ver 3...

Page 4: ...d Counter Optional I 87082 100 kHz max 32 bit Protocols Modbus Master Protocol Up to 2 COM Ports COM1 COM2 and COM3 in X board support Modbus RTU ASCII Master protocol to connect to other Modbus slave I O devices Max Mbus_xxx Function Block amount 64 Modbus Slave Protocol Up to 2 COM Ports COM1 and one of COM2 COM3 in X board can support Modbus RTU Slave protocol for connecting ISaGRAF PC HMI OPC ...

Reviews: