I-7242D user manual
I-7242D DeviceNet/Modbus RTU Gateway User’s Manual, July 2006, Version 1.1 88/124
2. Apply the Master’s Explicit Request Messages to change the Slave’s
Baud Rate.
Master
(MAC
ID
=0x0A)
Slave
(MAC
ID
=0x09)
Note:
After finishing the change of the MAC ID on-line, the I-7242D will send a
shutdown message and reset. However if users want to change the baud rate
of I-7242D, they must send the reset service to reset the I-7242D. Then the
new baud rate of the I-7242D will become effective.
_ Group 2 Message
| _ Destination MAC ID=0x09
| | _ Message ID =4
| | | _ Frag=0. Transaction ID=0. Destination MAC ID= 0x0A
| | | | _ Service=Set Attribute Request
| | | | | _ Class ID=3
| | | | | | _ Instance ID=1
| | | | | | | _ Attribute ID=2
| | | | | | | | _
Attribute Data= 0x01 -- New Baud Rate
ID=10 001001 100. Data= 0A 10 03 01 02
01
_ Group 2 Message
| _ Source MAC ID=0x09
| | _ Message ID =3
| | | _ Frag=0. Transaction ID=0. Destination MAC ID= 0x0A
| | | | _ Service= Set Attribute Response
| | | | |
| | | | |
ID=10 000011 011. Data= 0A 90