System Specifications 

 

CPU Module 

CPU 

32-bit MCU 

Wi-Fi 

Antenna 

Omni-Directional 

3 dBi @ 2.4 GHz 

5.5 dBi @ 5 GHz 

Channels 

2.4 GHz: CH1~11 

5 GHz: CH36

40

44

48 

Encryption 

Open/WPA/WPA2 

Operation Mode 

Limit-AP & Infrastructure 

Standards 

IEEE 802.11 a/b/g 

Transmission Range 

50 m (LOS) 

COM Ports 

Ports 

1 x RS-232 

1 x RS-485 

1 x RS-422 

Baud Rate 

115200 bps Max. 

Parity 

None, Odd, Even 

Data Bit 

7, 8 

Stop Bit 

1, 2 

Ethernet 

Ports 

1 x RJ-45, 10/100 Base-TX, 8-pin 

Power 

Input Range 

+10 ~ 30 VDC 

Consumption 

0.05 A @ 24 VDC 

Mechanical 

Dimensions (mm) 

33 x 106 x 120 (W x L x H) 

Installation 

DIN-Rail 

Environmental 

Summary of Contents for ICP CON RMV-762D-MTCP

Page 1: ...RMV 762D MTCP Module User Manual Version 1 0 0 Jan 2021 1 Copyright 2021 by ICP DAS Co Ltd All rights are reserved RMV 762D MTCP User Manual...

Page 2: ...ulting from the use of this product ICP DAS reserves the right to change this manual at any time without notice The information published by ICP DAS is believed to be accurate and reliable However no...

Page 3: ...1 0 0 Jan 2021 3 1 Introduction 4 1 1Features 5 2 Hardware Information 6 2 1System Specifications 6 2 2Hardware Specification 7 2 3Wiring Connection 8 2 4Dimension Units mm 9 2 55 Digital 7 Segment L...

Page 4: ...s The RMV 762D TCP built in Wi Fi 802 11a b g function can be applied to the already Wi Fi system It can connect to the remote equipment by Wi Fi AP to reduce the wire cost The RMV 762D TCP built in W...

Page 5: ...ake the Modbus TCP connection with their Modbus TCP client and exchange the Modbus command to the Modbus RTU slave from the Modbus RTU master side Modbus RTU Slave Modbus TCP Client User can make the...

Page 6: ...40 44 48 Encryption Open WPA WPA2 Operation Mode Limit AP Infrastructure Standards IEEE 802 11 a b g Transmission Range 50 m LOS COM Ports Ports 1 x RS 232 1 x RS 485 1 x RS 422 Baud Rate 115200 bps...

Page 7: ...7 Operating Temperature 25 75 C Storage Temperature 30 80 C 2 2 Hardware Specification...

Page 8: ...8 2 3 Wiring Connection...

Page 9: ...9 2 4 Dimension Units mm...

Page 10: ...onnection Server and Pair Connection Client types Each type is shown as Ethernet Limit AP and the infrasturcture modes Main Function Dispaly 7 segment LED Display Description Initial Settings Limit AP...

Page 11: ...Port Settings b 01 is the baudrate 115200 bps b 02 is the baudrate 57600 bps b 03 is the baudrate 38400 bps b 04 is the baudrate 19200 bps b 04 is the baudrate 9600 bps L 01 is the data bits 7 L 02 is...

Page 12: ...s the stop bit 1 S 02 is the stop bit 2 RSSI Value Error Code Please refer to the appendix When the module is boot up the LED is displayed the following steps Step 7 segment LED Display Description 1...

Page 13: ...Slave Modbus TCP Client 3 Vxcomm Server 4 It shows the IP address of Ethernet LAN port For example the IP configurations are IP address 192 168 255 1 Subnet Mask 255 255 0 0 Gateway 192 168 255 254 IP...

Page 14: ...Wi Fi interface For example the IP configurations are IP address 192 168 255 2 Subnet Mask 255 255 0 0 Gateway 192 168 255 254 IP 2 Wi Fi IP Settings example IP address 192 168 255 2 Subnet Mask 255...

Page 15: ...15...

Page 16: ...serial configurations are Baudrate 115200 bps Data bit 8 Stop bit 1 Parity None The serial configurations are Baudrate 115200 bps Data bit 8 Parity None Stop bit 1 7 Return the Wi Fi RSSI value For E...

Page 17: ...pe the Ethernet IP address of the RMV 762D MTCP and connect it for settings 2 Ethernet Settings If the DHCP is disable user can type the static IP of the LAN port to the RMV 762D MTCP 3 Wi Fi Settings...

Page 18: ...port connection 115200 57600 38400 19200 9600 bps Data Bits The data bits of the serial port connection 8 7 Parity The parity of the serial port connection None Odd Even Stop Bits The stop bits of th...

Page 19: ...lowing step for upgrade Step 1 Switch to the Init mode and reboot Step 2 Click the FW Update button Step 3 Select the firmware file and clieck the Download button Do not save the firmware file with th...

Page 20: ...ture mode 00002 Modbus RTU communication error 00003 Modbus TCP connection loss 00004 Low RSSI ICP DAS Web Site http www icpdas com Contact Us E Mail Service icpdas com ICP DAS Web Site http www icpda...

Reviews: