Zero-Initialization setting 

 

1. Connect the iXN-2VB3 to iWSN-100X-CLE or  iWSN-101X-CLE. 

(Hereinafter referred to as the transmitter) 

2. Clear  the  zero-initialization  setting  first.  (set  the  F1/F2  pin  to 

ON, then turn on the transmitter power) 

3. Read  the  register  of  iWSN-200x,  will  get  a  value  not  close  to 

zero. 

PLC 

address 

(Base1) 

Protocol 

address 

(Base0) 

Data 

Data type 

Description 

40257 
30257 

256 

(0x

01

00) 

36 

Uint16 

Mean value: X 

40258 
30258 

257 

(0x

01

01) 

18 

Uint16 

Mean value: Y 

40259 
30259 

258 

(0x

01

02) 

94 

Uint16 

Mean value: Z 

4. iXN-2VB3 is fixed at the location to be measured and kept flat 

and still. 

5. Make the zero-initialization setting. (Set F1 pin to ON / F2 pin to 

OFF, then turn on the transmitter power) 

Item 

Name 

Instructions 

F1   
F2 

(Clear the 

zero-initialization setting) 

■:

ON   

□:

OFF 

 

PWR

 

ON

Power on     

 

Item 

Name 

Instructions 

F1   

(zero-initialization 

setting) 

■:

ON   

□:

OFF 

 

F2 

(zero-initialization 

setting) 

□:

ON   

■:

OFF 