M-7084 User Manual, Rev. A1.3 7PH-013-A13
61
2.16 $AA7VV
Description:
Specifies the channels which counter overflow status are to be
cleared.
Syntax:
$AA7VV[CHKSUM](CR)
$
Delimiter character
AA
Address of the module to be read (00 to FF)
7
Command to clear the counter overflow status
VV
A two-digit hexadecimal value, where bit 0
corresponds to channel 0, bit 1 corresponds to
channel 1, etc. When the bit is 1 it means that the
counter overflow status of the channel should be
cleared.
Response:
Valid Command:
!AAVV[CHKSUM](CR)
Invalid Command:
?AA[CHKSUM](CR)
!
Delimiter character for a valid command
?
Delimiter character for an invalid command
AA
Address of the responding module (00 to FF)
There will be no response if the command syntax is incorrect,
there is a communication error, or there is no module with the
specified address.