M-7026
M-7026 User Manual Rev: 1.5 Date: 2016/03/10
161
3.6.1 Sub-function 00 (0x00) - Read the Name of
the Module
This sub-function code is used to read the name of the module.
Request
00
Address
1 Byte
1 to 247
01
Function Code
1 Byte
0x46
02
Sub-function Code
1 Byte
0x00
Response
00
Address
1 Byte
1 to 247
01
Function Code
1 Byte
0x46
02
Sub-function Code
1 Byte
0x00
03 - 06 Module Name
4 Bytes
0x00 0x70 0x02 0x00
Error Response
00
Address
1 Byte
1 to 247
01
Function Code
1 Byte
0xC6
02
Exception Code
1 Byte
03: An incorrect number of bytes were
received
Summary of Contents for M-7026
Page 8: ...M 7026 User Manual Rev 1 5 Date 2016 03 10 8 1 3 Pin Assignments...
Page 12: ...M 7026 User Manual Rev 1 5 Date 2016 03 10 12 1 5 Block Diagram...
Page 13: ...M 7026 User Manual Rev 1 5 Date 2016 03 10 13 1 6 Application Wiring...
Page 43: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 43 Section 1 8 1 Analog Input Calibration...
Page 47: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 47 Section 5 1 INIT Mode...
Page 90: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 90 Section 5 2 Dual Watchdog Operation...
Page 113: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 113 Section 2 68 AARECi...
Page 127: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 127 Section 2 62 AADODD...
Page 129: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 129 Related Commands Section 2 61 AADI...
Page 141: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 141 Related Commands Section 2 53 AACECi...
Page 180: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 180...
Page 183: ...M 7026 M 7026 User Manual Rev 1 5 Date 2016 03 10 183...