Output Range Setting (JP5/JP9)
After the configuration of reference voltage source, the practical voltage output
range of PISO-DA2/DA2U can be regulated as either Bipolar or Unipolar by
jumper JP5 and JP9. The detail setting is demonstrated in Table 2-5.
For example, if the jumper “JP4” and “JP5” are set as “-5 V” and “Unipolar”
respectively, then the range of voltage output is 0~5 V for channel 1.
Table 2.5: Output range setting
Channel
Channel 1
Channel 2
Unipolar
( Default)
Bipolar
JP5
BP
UP
JP5
BP
UP
JP9
BP
UP
JP9
BP
UP
PISO-DA2/DA2U User Manual (Ver.2.7, Mar. 2012, PMH-020-27)
14