The following is an overview of the parameters contained in the Port1 Settings section:
Item
Description
Default
Port Settings
Baud Rate (bps)
This parameter is used to set the Baud Rate for the
COM ports.
115200
Data Size (bits)
This parameter is used to set the Data Size for the
COM ports.
8
Parity
This parameter is used to set the Parity for the COM
ports.
None
Stop Bits (bits)
This parameter is used to set the Stop Bits for the
COM ports.
1
Flow Control
This parameter is used to set the Flow Control for the
COM ports.
None
Allow Driver Control
Enable client (VxComm Driver) to dynamically change
the data format and baud rate settings.
Enable
Operation Mode
M0/Multi-echo
: Share received serial data between
clients.
M1/Single-echo
: Send received serial data to the
requested client only.
0 = Data-sharing; 1 = Non-sharing
0
Local TCP Port
TCP Command Port +1
Note:
COM1/COM2/COM3 = TCP port 10001/10002/10003
10001
Connection Idle (seconds)
If the Local TCP port does not receive any data via the
TCP/IP for a certain period, the tDS-700 will
disconnect the socket based on the TCP timeout
value.
Settings range: 1 ~ 65535 (seconds); Disabled: 0;
180
Prefix String
This parameter is used to set the first character in a
line of data.
Settings range: Max. 8 chars.
Serial Data Packing
Slave Timeout (ms)
Set the waiting time after last Tx of the request sent
to the device. If the device does not respond within
the timeout value, the tDS-700 will return existing
data via TCP package and process next request.
1000