Tiny Serial-to-Ethernet Device Server
Copyright © 2020 ICP DAS CO., Ltd. All Rights Reserved.
-56 -
The following is an overview of the parameters contained in the
IP Address Settings
section:
Item
Description
IP Address
Address Type
Static IP:
If no DHCP server is installed on the network, the network settings
can be configured manually. Refer to
for more
details.
DHCP:
The Dynamic Host Configuration Protocol (DHCP) is a network
application protocol that automatically assigns an IP address to each device.
Refer to
for more details.
Static IP Address
Each tDS-700/DS-2200 connected to the network must have its own unique IP
address. This parameter is used to assign a specific IP address.
Subnet Mask
This parameter is used to assign the subnet mask for the tDS-700/DS-2200
device. The subnet mask indicates which portion of the IP address is used to
identify the local network or subnet.
Default Gateway
This parameter is used to assign the IP Address of the Gateway to be used by
the tDS-700/DS-2200. A Gateway (or router) is a device that is used to connect
an individual network to one or more additional networks.
MAC Address
This parameter is used to set a user-defined MAC address, which must be in
the format FF-FF-FF-FF-FF-FF.
Virtual COM
TCP Command Port
This parameter is used to configure the TCP Command Port to a custom value
depending on your requirement. Note that if the TCP Command Port
configuration setting is completed, the TCP port of serial port will be change, as
follows:
COM1= TCP Command Port + 1
COM2= TCP Command Port + 2
The default TCP Command Port is 10000, Thus, the serial COM port1/port2 is
10001/10002, and so on.
Command Port Timeout
(Socket Watchdog)
If the command port does not receive any data from the TCP/IP socket for a
certain period, the tDS-700/DS-2200 can disconnect the socket.
Settings range value: 1 ~ 65535 (seconds);
Default value: 30 (seconds);
Disabled: 0;
Update Settings