Tiny Serial-to-Ethernet Device Server
Copyright © 2020 ICP DAS CO., Ltd. All Rights Reserved.
-59 -
Item
Description
Default
System Idle
(Network Watchdog)
This parameter is used to configure the system timeout value. If
there is no activity on the network for a specific period of time,
the system will be rebooted based on the configured system
timeout value.
Timeout value range: 30 to 65535 (seconds);
Disable = 0.
300
Web Auto-logout
This parameter is used to configure the automatic logout value.
If there is no activity on the web server for a certain period of
time, the current user account will be automatically logged out.
Range: 1 to 65535 (minutes);
Disable = 0.
10
CGI Configuration
The tDS-700/DS-2200 can be configured by CGI command. For
detailed CGI command and configuration information, refer to
Enable/Disable the assign.cgi.
Enable
UDP Configuration
This parameter is used to enable or disable UDP configuration
function.
Enable
UDP Alarm
Alarm IP Address (UDP)
The tDS-700/DS-2200 can send and UDP package (include alarm message) to
specified network location (Alarm IP Address/Port).
Alarm Port (UDP)
Misc.
Alias Name
This parameter is used to assign an alias for each tDS-700/
DS-2200 device to assist with easy identification.
Tiny
UART Watchdog
If the serial port does not communication occurs for a certain
period, the system will be rebooted based on the UART
Watchdog value.
Settings range: 30 ~ 65535 (seconds);
Disable: 0.
0
Debug Message(UDP)
Reserved.
20
Update Settings
Click this button to save the revised settings to the tDS-700/DS-2200.