4
916V/ 832A. For DC input power supply, you may choose: ACE-932T, ACE-925T,
ACE-925C or ACE-916V. ACE-R30A redundant power supply is optional.
Working Environment
- Operating Temperature
:
0~50°C environment
- Relative Humidity
:
5~95% Relative
- Vibration
:
5-17Hz, 0.1” double amplitude displacement
17-640Hz, 1.5G acceleration peak to peak
- Shock
:
10G-acceleration peak to peak
- Safety approval
:
meet CE, FCC
Cooling Fan
Two removable ball bearing cooling fan (8cmX8cm)
Drive Capacity
Three 5.25” drive and one 3.5” open FDD or HDD space.
Programmable Message and Alarm Function
EC-1040 provides customer a programmable display for server name, IP address,
system time, alarm message,… etc. We can use the utility tool to program message
by RS-232 port. The detail please references the section 2-7 cable management for
system internal connection. The floppy disk (A106 Utility) provides the setting
programming information.
The alarm function support system monitoring that four fan speed monitoring, two
Temp. monitoring, alarm buzzer, alarm message and customer message transfer to
LCD module.
Summary of Contents for EC-1040
Page 1: ...EC 1040 CHASSIS USER S MANUAL ...
Page 6: ...5 1 3 Dimensions TEMP LED LAN LED FAN LED BUZZER OFF ...
Page 9: ...8 EC 1040 EC 1040 DM 62M ...
Page 10: ...9 POWER MENU DOWN EXIT LCD ON OFF U P EC 1040 DM 64T ...
Page 11: ...10 EC 1040 DM 62M KM 085 ...
Page 12: ...11 EC 1040 KM 085 ...
Page 17: ...16 2 6 2 Redundant Power Supply for the EC 1040 installation ACE R30A SCREW X 2 ...
Page 20: ...19 A106 G04 Controller A106 Alarm board G04 LED board ...
Page 21: ...20 ...
Page 23: ...22 BP 14S Serial PX 14S Serial ...
Page 26: ...25 APPENDIX C Drive Bay 5 25 Drive Bay 3 open space 3 5 Drive Bay 2 open 1 Internal space ...