3

440 04 2023 02

Specifications are subject to change without notice

Circulation Air Blower Data - *9MPT

*9MPT050F12

(1) *

Denotes Brand

Speed

Tap

Low

Med L

Med H

Hi

0.1

826

1083

1301

1408

0.2

804

1050

1242

1347

0.3

770

1028

1195

1295

0.4

735

985

1153

1237

0.5

698

952

1093

1183

0.6

657

909

1040

1118

0.7

------

863

935

1053

0.8

--------

812

865

976

0.9

------

------

802

887

1.0

------

------

720

787

*9MPT100J16

(1) *

Denotes Brand

Speed

Tap

Low

Med L

Med H

Hi

0.1

823

1109

1527

1850

0.2

795

1087

1482

1791

0.3

747

1056

1426

1720

0.4

677

1016

1382

1648

0.5

617

970

1317

1575

0.6

544

854

1245

1485

0.7

------

763

1154

1401

0.8

------

652

1043

1284

0.9

------

------

905

1161

1.0

------

------

737

1028

*9MPT075F14

(1) *

Denotes Brand

*9MPT125L20

(2) *

Denotes Brand

Speed

Tap

Low

Med L

Med H

Hi

0.1

695

1025

1455

1724

0.2

674

1001

1410

1662

0.3

653

951

1365

1601

0.4

631

921

1309

1530

0.5

609

891

1252

1460

0.6

569

845

1187

1380

0.7

529

799

1122

1300

0.8

490

730

1030

1190

0.9

------

680

950

1080

1.0

------

------

831

969

NOTE: (1) Data based on Bottom Only or One Side return.

(2) Data based on Both Sides or Bottom plus One Side

MAX CFM’s for Factory

Washable Filters

Filter Size

CFM

14

X 25

1400

16

X 25

1600

20

X 25

2000

24

X 25

2500

Max CFM based on 600 FPM

NOTE: Disposable filters are typically rated at 300 FPM. These filters only allow

half the airflow when compared to 600 FPM filters. (EXAMPLE, 20 X 25 @ 600

FPM = 200 CFM, @ 300 FPM = 1000 CFM)

Speed

Tap

Low

Med L

Med H

Hi

0.1

1720

1910

2127

2315

0.2

1686

1881

2087

2268

0.3

1644

1833

2024

2201

0.4

1600

1777

1961

2131

0.5

1533

1720

1891

2029

0.6

1494

1647

1804

1948

0.7

1413

1571

1708

1820

0.8

1306

1470

1604

1730

0.9

------

1349

1484

1614

1.0

------

------

1328

1430

# CFM -- Cubic feet per minute airflow. Filter required for each return--air

inlet. Airflow performance includes 1

washable (600 FPM max) filter media.

Summary of Contents for C9MPT050F12C1

Page 1: ...MPV125L20D1 Denotes Brand C H T Save This Manual For Future Reference Four Position Furnace International Comfort Products LLC Lewisburg TN 37091 U S A Technical Support 9MPT 2 Circulation Air Blower...

Page 2: ...90 DWV Elbows Blower Transition Box LO Heat Std Pressures in wc 5 No Elbows 40 5 90 DWV Elbows 1 80 2 60 1 30 2 30 1 20 1 90 1 00 1 80 1 80 2 60 1 30 2 30 1 20 1 90 1 00 1 80 1 80 2 60 1 70 2 50 1 20...

Page 3: ...0 1 695 1025 1455 1724 0 2 674 1001 1410 1662 0 3 653 951 1365 1601 0 4 631 921 1309 1530 0 5 609 891 1252 1460 0 6 569 845 1187 1380 0 7 529 799 1122 1300 0 8 490 730 1030 1190 0 9 680 950 1080 1 0 8...

Page 4: ...4 440 04 2023 02 Specifications are subject to change without notice Wiring Diagram 9MPT Two Stage Heating with PSC Motor...

Page 5: ...ice 9MPT Parts 25 24 75a 4 YY WW N LL 11 18 V W R S T U J L JJ Q P Y X F UU VV TT SS H RR QQ KK 5 4 3 9 10 M K 2 1 B A 7 D K 6 HH 8 ZZ 13 15 FF EE 16 BB 12 16 GG 17 DD CC FF 14 O N O F F OO 20 NN PP M...

Page 6: ...ellyband location on motor Bellyband Location on Motor Model 9MPT A in 050F12 2 09 075F14 1 81 100J16 1 81 125L20 1 65 Key No Description Non Functional Part Number 9MPT 050 F12 075 F14 100 J16 125 L2...

Page 7: ...ube Drain Coll Box 5 8 ID 1172245 1 1 1 1 UU Tube Drain Tee 1 2 ID 1171989 1 1 1 1 VV Tube Relief 1172012 1 1 1 1 WW Drain Vent 1014003 1 1 1 1 ZZ Sightglass 1172768 1 1 1 1 YY Tee Drain 1171915 1 1 1...

Page 8: ...ower Transition Box HI Heat Std Pressures in wc 5 No Elbows 40 5 90 DWV Elbows Blower Transition Box LO Heat Std Pressures in wc 5 No Elbows 40 5 90 DWV Elbows 1 80 2 60 1 30 2 30 1 20 1 90 1 00 1 80...

Page 9: ...oling calls Note 3 Low Heat ESP is a result of High Heat ESP is decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at factory...

Page 10: ...1200 1400 1600 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 ESP in w c CFM 00 00 NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 Legend Airflow Selection is from Highest to Lowest Low Cooling Airflows 9MPV05...

Page 11: ...ling calls Note 3 Low Heat ESP is a result of High Heat ESP is decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at factory...

Page 12: ...1400 1600 1800 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 ESP in w c CFM 00 00 NOM 01 00 01 NOM 10 01 10 NOM 11 10 11 NOM 11 Legend Airflow Selection is from Highest to Lowest Low Cooling Airflows 9MPV07...

Page 13: ...g cooling calls Note 3 Low Heat ESP is a result of High Heat ESP is decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at fac...

Page 14: ...0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 ESP in w c CFM 00 00 NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 Legend Airflow Selection is from Highest to Lowest Low Cooling Airflows 9MPV100J20 0 200 400...

Page 15: ...g cooling calls Note 3 Low Heat ESP is a result of High Heat ESP is decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at fac...

Page 16: ...0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 ESP in w c CFM 00 00 NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 Legend Airflow Selection is from Highest to Lowest Low Cooling Airflows 9MPV125L20 0 200 400...

Page 17: ...URNACE CONTROL 24VAC RED FROM 24V TRANS RED HP MODE AC HP EFFICIENCY HP COMFORT J2 NOM BLOWER ADJUST J1 Y1 O AC HP EFFICIENCY HP COMFORT J2 NOM J1 1 2 3 4 6 5 7 8 SELECT SELECTION BLOWER ADJUST INCREA...

Page 18: ...18 440 04 2023 02 Specifications are subject to change without notice Wiring Diagram 9MPV Variable Speed Blower Motor...

Page 19: ...notice 9MPV Parts 25 25 32b YY WW N LL 11 18 V W R S T U J L JJ Q P Y X F UU VV TT SS H RR QQ KK 5 9 10 M K 2 1 B A 8 6 HH K 23 OO 20 MM PP NN ZZ 22 4 3 13 15 FF EE 16 BB 12 16 GG 17 DD CC FF 14 21 R...

Page 20: ...rol Motor Variable Spd 1174887 1174888 1174889 1174895 1 1 1 1 23 Choke Power 1172838 1 1 See Table below for bellyband location on motor Bellyband Location on Motor Model 9MPV A in 050F12 13 8 075F12...

Page 21: ...71987 1 1 1 1 TT Tube Drain Coll Box 5 8 ID 1172245 1 1 1 1 UU Tube Drain Tee 1 2 ID 1171989 1 1 1 1 VV Tube Relief 1172012 1 1 1 1 WW Drain Vent 1014003 1 1 1 1 YY Tee Drain 1171915 1 1 1 1 ZZ Sightg...

Reviews: