6
440 01 4201 03
Specifications subject to change without notice.
Figure 2
Dimensions
6 15/16 [176.1]
3
[76.2]
3
[76.2]
6 11/16 [170.1]
23 5/16 [592.9]
25 1/8 [638.7]
26 3/8 [670.0]
26 11/16 [678.1]
21
[534.0]
26 5/16 [668.8]
17 5/16 [439.2]
16 9/16 [420.9]
20 1/4 [513.9]
25 3/16 [639.1]
28 3/16 [715.9]
28 5/8 [726.4]
32 5/8 [829.5]
28 3/4 [730.5]
26 3/8 [669.9]
26 11/16 [678.1]
21 15/16 [557.4]
21 1/16 [535.8]
26 5/16 [668.8]
3
[76.2] AIR INTAKE
1 3/4
[44.5] GAS CONN
7/8
[22.2]
7/8
[22.2] POWER CONN
7/8
[22.2]
THERMOSTAT ENTRY
7/8
[22.2]
3
[76.2]
AIR INTAKE
1 3/4
[44.5] GAS CONN
7/8
[22.2]
7/8
[22.2]
3
[76.2 ]
7/8
[22.2]
7/8
[22.2] THERMOSTAT ENTRY
22 15/16 [581.9]
16 9/16 [420.9]
17 7/16 [442.3]
20 1/4 [513.9]
24
[609.7]
28 3/8 [720.4]
28 5/8 [726.9]
29 13/16
[757]
23 3/8 [592.0]
3
[76.2] VENT
1 (BOTH SIDES)
[25.4]
D
2 3/10 [58.4]
C
BOTTOM RETURN
WIDTH
11/16 [17.5]
11/16 [17.5]
B
OUTLET WIDTH
A
22
[558.3] (BOTH SIDES)
14 13/16 [376.3]
35
[889.0]
5/8 [15.8]
1 5/16 [33.3]
29 1/2 [749.3]
19 1/8 [485.8]
20 5/8 [522.7]
23 7/16 [595.6]
[101.6]
4
[63.5]
2 1/2
18 1/16 [458.6]
2 1/2 [63.5]
4
[101.6]
20 5/8 [522.7]
BOTTOM INLET
21 5/8 [549.5]
6 1/16 [154.0]
CONDENSATE DRAIN TRAP LOCATION
NOTE: ALL DIMENSIONS IN INCH [MM]
[22.2]
7/8
7/8
[22.2] POWER CONN
AIR FLOW
SEE NOTE #3
TOP VIEW
NOTES: 1. Doors may vary by model. 2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters. a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle. b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle. c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle. d. Return air above 1800 CFM at 0.5 in. w.c. ESP on 24.5" casing, requires one of the following configurations: 2 sides, 1 side and a bottom or bottom only. See Air Delivery table in this document for specific use to allow for sufficient airflow to the furnace. 3. Vent and Combustion air pipes through blower compartment must use accessory “Vent Kit - Through the Cabinet”. See accessory list for current part number.
SD5060
−
4
(F/G9MAC)
FURNACE SIZE
A
B
C
D
SHIP WT.
LB (KG)
CABINET
WIDTH
OUTLET WIDTH
BOTTOM
INLET WIDTH
AIR INTAKE
0601714
17
−
1/2 (445)
15
−
7/8 (403)
16 (406)
8 3/4 (222)
154 (69)
0602120
21 (533)
19
−
3/8 (492)
19
−
1/2 (495)
10 1/2 (267)
159 (72)
0801714
17
−
1/2 (445)
15
−
7/8 (403)
16 (406)
8 3/4 (222)
164 (74)
0802120
21 (533)
19
−
3/8 (492)
19
−
1/2 (495)
10 1/2 (267)
169 (77)
1002122
21 (533)
19
−
3/8 (492)
19
−
1/2 (495)
10 1/2 (267)
179 (80)
1202422
24
−
1/2 (622)
22
−
7/8 (581)
23 (584)
12 1/4 (311)
203 (91)