Table 1 – Kit Contents
DESCRIPTION
PART NO.
QTY
Sealing tape
2
External extension harness
327962701
1
Main twinning harness
327957701
1
Secondary twinning harness
327959701
1
Twostage furnace wiring diagram
337068101
1
Single stage furnace heat wiring
diagram
337070101
1
Single stage furnace/twostage
heat wiring diagram
337069101
1
Label
327956101
1
Tape
1
Bag Assembly includes:
Snap bushing
2
Screws (HEX HD 6B X ¾)
10
Screws (flat head)
1
Wire tie
4
Clamps
2
Installation Instructions
1
Auxiliary door switch bracket
1
NOTE
: As a result of staged heating with single
−
speed
furnaces, the air temperature distribution in the supply plenum
may be uneven when only 1 furnace is heating.
NOTE
: Refer to the Installation, Start
−
Up, and Operating
Instructions supplied with each furnace for information on
venting, clearances, start
−
up, maintenance, and other
information not covered in this publication.
See Table 1 for kit contents.
ELECTROSTATIC DISCHARGE (ESD) PRECAUTION
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit and
component damage.
Failure to follow this caution could result in unit and
component damage. Electrostatic discharge can affect
electronic components. Take precautions during furnace
installation and servicing to protect the furnace
electronic control. Precautions will prevent electrostatic
discharges from personnel and hand tools which are
held during the procedure. These precautions will help
to avoid exposing the control to electrostatic discharge
by putting the furnace, the control, and the person at the
same electrostatic potential.
CAUTION
!
1. Disconnect all power to the furnace. DO NOT TOUCH
THE CONTROL OR ANY WIRE CONNECTED TO THE
CONTROL PRIOR TO DISCHARGING YOUR BODY’S
ELECTROSTATIC CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the
furnace chassis which is close to the control. Tools held
in a person’s hand during grounding will be satisfactorily
discharged.
3. After touching the chassis you may proceed to service
the control or connecting wires as long as you do
nothing that recharges your body with static electricity
(for example; DO NOT move or shuffle your feet, DO
NOT touch ungrounded objects, etc.).
4. If you touch ungrounded objects (recharge your body
with static electricity), firmly touch furnace again before
touching control or wires.
5. Use this procedure for installed and uninstalled
(ungrounded) furnaces.
6. Before removing a new control from its container,
discharge your body’s electrostatic charge to ground to
protect the control from damage. If the control is to be
installed in a furnace, follow items 1 through 5 before
bringing the control or yourself into contact with the
furnace. Put all used AND new controls into containers
before touching ungrounded objects.
7. An ESD service kit (available from commercial sources)
may also be used to prevent ESD damage.
SECTION I: MULTIPOISE SINGLE
−
SPEED AND
TWO
−
SPEED NON
−
CONDENSING HSI FURNACE
MODELS
SINGLE
−
STAGE
TWO
−
STAGE
N8MSN
F8MTL
N8MSL
G8MTL
NOTE
: Throughout these instructions, when the furnace
installed side
−
by
−
side, the left
−
hand (LH) side will be referred
to as the LH furnace, and the furnace installed on the
right
−
hand (RH) side as the RH furnace. When the furnaces
are installed back
−
to
−
back, the left
−
hand (LH) side will be
referred to as the LH furnace, and the furnace installed on the
right
−
hand (RH) side as the RH furnace when viewed from the
side with the extension harness installed.