HT10
EN - 9
5.2. AC VOLTAGE MEASUREMENT
CAUTION
The maximum input for AC Voltage is 1000V. Do not measure higher
voltages to avoid risks of electrical shocks or serious damages to the
instrument
Warning LED turns ON and the buzzer sound for voltage between
probes over 50V
Fig. 5: AC Voltage measurement
1. Perform the preliminary Autotest function (see § 4.4)
2. Connect the
L1
and
L2
probes to the object under test (see Fig. 5). The measurement
is performed
only with contact of probes directly on metal parts of conductors
3. The instrument switches on automatically on for voltage >6V and the AC voltage value
is displayed both through red LEDs switching on and on the display. AC symbol is
displayed
4. The LED
and the “AC” indication switch on, the AC voltage measurement is
displayed and an acoustic signal is emitted
5. The instrument turns automatically OFF as soon as probes are disconnected from the
object under test
6. For measurements in single-phase plants the LEDs
or
can turn on This is not a
device problem
7. Press the
H/
key to enable the HOLD function at display. Press and hold the
H/
key
in order to activate/deactivate the display backlight
8. Press the
/
key to activate/deactivate the white LED torch
Summary of Contents for HT10
Page 2: ......
Page 4: ......
Page 5: ...Copyright HT ITALIA 2019 Versione IT 1 01 09 05 2019 ITALIANO Manuale d uso...
Page 24: ......
Page 25: ...Copyright HT ITALIA 2019 Release EN 1 01 09 05 2019 ENGLISH User manual...
Page 44: ......
Page 45: ...Copyright HT ITALIA 2019 Versi n ES 1 01 09 05 2019 ESPA OL Manual de instrucciones...
Page 64: ......
Page 65: ...Copyright HT ITALIA 2019 Ausf hrung DE 1 01 09 05 2019 DEUTSCH Bedienungsanleitung...
Page 84: ......
Page 85: ...Copyright HT ITALIA 2019 Version FR 1 01 09 05 2019 FRAN AIS Manuel d utilisation...
Page 104: ......
Page 105: ...Copyright HT ITALIA 2019 Vers o IT 1 01 09 05 2019 PORTUGU S Manual de utiliza o...
Page 124: ......