Program number table
18/24
8. Program number table
The program table lists all the program numbers (PN) with their function, range of values,
default values and user level.
PN Function
Range of value
Def-
ault
User
level
Channel 1
0
Measuring input
Parameters 1 to 4 make use of the
factory calibration
.
Current, Voltage
0 = Sensor calibration
1 = 0...20 mA
2 = 4...20 mA
3 = 0...10 V
4 = 0....5 V
2 2
1
Final value respectively fullscale
-999...9999
1000
2
2
Zero point respectively offset
-999...9999
0
2
3
Number of decimal places
0 = 0
1 = 0.0
2 = 0.00
3 = 0.000
0 2
5
Offset shift on display value
-999…9999
0
2
10
Zero point suppression
0…999
0
2
General settings
13
Display time
0.1 ... 10.0
1.0
2
14
Measuring time
0.01 ... 10.0
1.0
2
Security settings
50 Programming
lock
0000...9999
0000 8
51 Access
code
0000...9999
0000 0
52 User
level
1...8
8
0
Threshold behaviour of LED display
54
Actuator via zero key
0 = deactivated
1 = TARA
2 = Offset shift
3 = HOLD
0 2
59
Display flashing (approx. 0.5 seconds)
No flashing
Flashes at setpoint 1
Flashes at setpoint 2
Flashes at setpoint 1 and 2
0 no flashing
1 flashes at 1
2 flashes at 2
3 flashes at 1 and 2
Setpoint 1
60
Setpoint 1
0 = deactivated
1 = activated
1 4
61 Threshold
-999...9999
1000 6
62 Hysterisis
1...9999
1
5
63
Active below / above threshold value
0 = active below
1 = active above
1 4
64
Switch delay in seconds
0…1000 seconds
1
4