Electrical connection
4/24
3.
Assembly
The wall-type housing consists of an upper part and a lower part. A suitable seal has been
inserted in the lower part to achieve protection IP66. In the upper part is the
IAKV
-2VR4C
with its operating and display elements. On the back are the terminals for
all the electrical connections. The
IAKV
-2VR4C
is intended for wall mounting.
3.1. Dimensions
3.2.
Assembly of the wall-type housing
I.
Before mounting the unit, the side flaps covering the area, where the screws are
located, must be flapped open to the left and right.
II.
With a suitable screw driver loosen the 4 fixing screws, joining the upper to the lower
section. Now the upper part can be removed from the lower part. The upper section
is connected to the lower section via a catch support, facilitating subsequent cable
assembly on the
IAKV
-2VR4C
unit, which is hanging downwards.
III.
In the next step, in accordance with the above diagram, 4 holes should be drilled for
the screws. After this you can mount the housing on the wall with the PG screws
aligned upwards.
IV.
Now the connecting cables can be fed via the PG screws to the unit and connected
to the screw clamp terminal in line with the connection diagram.
V.
After successfully mounting the lower section, lift up the upper section with the
IAKV
-2VR4C
and place it on the lower section. Using the 4 fixing screws, screw the
upper
part to the lower part. Take care that the screws are completely tightened in
order to
attain protection IP66. Finally, fold the cover flaps inwards again.
160 mm
130
m
m
Housing depth = 60 mm